Common fault analysis of centrifugal cryogenic liquid pump

Common fault analysis of centrifugal cryogenic liquid pump
Sep 03, 2025
Author: DEAR AST
Question Reply

In the air separation unit, low-temperature liquid is transported by centrifugal cryogenic pump. In order to ensure the reliable operation of the equipment, two sets of low-temperature pumps are generally equipped, one for use and one for standby. During normal operation, the main pump runs at full load, and the standby pump is in standby state under low load operation. Since the working medium temperature of cryogenic liquid pump is about -180°C, the working pressure is very high, and the pump body is installed in the cold box. When the pump fails, it is extremely difficult to maintain. Therefore, how to maintain the stable and reliable operation of cryogenic liquid pump is of great significance.

1.Common faults and cause analysis

Fault Condition

Causes of failure

Cavitation

low inlet pressure, deviation from the best working point, improper installation height, inadequate cold insulation measures of inlet pipeline, etc

Seal abnormal

seal aging and abnormal vibration damage seal

Abnormal pumping capacity

impeller damage, shaft seal leakage, low pump load and speed

Bearing overheating

excessive lubricating grease, friction caused by improper clearance, shaft vibration caused by shaft bending or poor coupling alignment

Shaft temperature too low

cooling capacity leaks out

 

2.Daily maintenance

Maintenance Measures

Concrete Content

Regular barring

Before putting into operation, the cryogenic pump needs to be turned manually. When it is out of service for a long time, it should also be turned regularly to ensure its normal operation.

Seal gas put into operation

Select safe and reliable seal gas, adjust the seal gas pressure according to the standard, and pass the seal gas before the pump starts to ensure that the leakage gas temperature is within the normal range and the bearing temperature is normal.

Full Precooling

The liquid pump is started under low load. After running at low speed for a certain period of time, the speed is increased step by step, and the pump is cooled by increasing the liquid return flow in the pump.

Lubrication normal

Select the appropriate brand of lubricating oil, and add the lubricating oil regularly and quantitatively to ensure the normal oil level.

Heating slowly

When the equipment is shut down, a large amount of cryogenic liquid is left in the pump. In order to prevent overpressure caused by increasing the pressure in the pump after liquid vaporization, the liquid should be discharged in time. After the liquid is drained, the pump should be heated for standby.

Degreasing cleaning

For the liquid oxygen pump, because the working medium is liquid oxygen, the pump should be strictly degreased during installation. The degreasing agent is perchloroethylene or trichloroethylene solvent.

DEAR Air Separation Solve YourCommon fault analysis of centrifugal cryogenic liquid pumpYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What is the Air separation unit instrument cluster and what is the relationship between transmitters, display tables, regulators, and membrane control valves?Air separation unit.1 g potassium dichromate or 2 g sodium nitrite can be added to each liter of water (not suitable for nonferrous metal degreasing); due to the toxicity or explosion of degreasing agent, attention must be paid to prevent poisoning and formation of explosive mixture. In alkaline cleaning, the pipeline with more oil stains is heated to 60-90 ℃ with 10% sodium hydroxide solution, then neutralized with 15% nitric acid and washed with clean water.Air separation unit.From the vaporization temperature (saturation temperature) of liquid oxygen, if the liquid oxygen surface is too high, the greater the static pressure difference between the upper and lower liquid oxygen surface, the higher the average pressure of liquid oxygen and the corresponding saturation temperature. In order to maintain the heat transfer temperature
2026.11.02
The air in nature is not absolutely dry, and a certain amount of gaseous water vapor is always mixed inside, which is a conventional part of air. Under normal pressure and normal temperature, water vapor is evenly dispersed in the air and will not condense into liquid water, so we cannot directly observe water. In the air separation operation, the air is first compressed by the air compressor. After the air is compressed, the volume is greatly reduced, and the density of water vapor in unit space increases sharply. At the same time, the saturated water content of air will change with the increase of pressure. Under high pressure, the upper limit of water vapor contained in air tends to be fixed. When the water vapor content exceeds the saturation value corresponding to the pressure, the air will reach the supersaturated state, which has the basis of water precipitation. The air compression process will generate a lot of heat, and the high temperature environment can temporarily improve
2026.10.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top