当前位置: Home / Faq / Air separation parts FAQ /

Analysis of vibration causes of pipeline of piston compressor and measures for vibration reduction

Analysis of vibration causes of pipeline of piston compressor and measures for vibration reduction
Jul 09, 2025
Author: DEAR AST
Question Reply

Users equipped with piston compressors often encounter the phenomenon of pipeline displacement, support deformation and severe noise caused by pipeline vibration, which has a negative impact on safety production. Therefore, it has great significance to thoroughly solve the vibration problem of the pipeline of the piston compressor to ensure the safe production of the air separation plant.

 

1.The reason analysis of pipeline vibration of piston compressor:

 

There are many reasons for pipeline vibration of piston compressor. According to many years of production practice and professional research, the main reason for the vibration of piston compressor is air flow pulsation. In addition, because the system composed of pipeline and internal gas has a certain natural frequency, if the excitation frequency of compressor is equal to or close to the natural frequency of the system, resonance will also occur, making the pipeline appear large amplitude.

 

2.Vibration reduction measures

 

1)A buffer tank can bearranged near the exhaust port of the compressor cylinder, which can effectively isolate the compressor cylinder from the pipeline and reduce the pulsating air flow through the buffer tank.

 

2)Adding a proper size orifice plate at the buffer inlet can reduce the pressure pulsation in the pipeline and enhance the buffer effect of the buffer.

 

3)Adding a resonator between the compressor cylinder and the buffer can essentially reduce the gaspulsation of the pipeline.

 

Users of DEAR air separation can select the above methods according to their own conditions, and reasonably formulate control measures to eliminate the potential safety hazards caused by compressor pipeline vibration.

DEAR Air Separation Solve YourAnalysis of vibration causes of pipeline of piston compressor and measures for vibration reductionYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top