当前位置: Home / Faq / Air separation parts FAQ /

What kinds of types of motors are commonly used in the air separation plant and in what occasions?

What kinds of types of motors are commonly used in the air separation plant and in what occasions?
Dec 16, 2024
Author: DEAR AST
Question Reply

InAir separation equipmentAlmost all the commonly used motors are three-phase AC motors. Three-phase AC motor can be divided into asynchronous motor and synchronous motor. The rotating speed of the synchronous motor and the frequency of the power grid keep a strict relationship, namely:
n=60f/P
In the formula, P -- magnetic pole logarithm;
F -- grid frequency, the normal situation is 50Hz;
N -- motor speed, r/min.
For example, for two-pole (P = 1) synchronous motor, the synchronous speed is 3000r/min; for four-pole motor, P = 2, n = 1500r/min. While the rotating speed of asynchronous motor is always less than that of synchronous motor, and it generates rotating torque by its phase difference.
Asynchronous motor is most widely used. It consists of a stator and a rotor, and has a stator and a rotor winding respectively. The stator winding is made of copper (aluminum) wire with outsourcing insulation. With the difference of rotor winding, asynchronous motor can be divided into squirrel cage type and winding type. Squirrel Cage motor rotor winding is like a cage, usually cast. Winding motor rotor winding is made of insulated wire, and the end of each phase of three-phase winding leads a wire to the slip ring.
Squirrel Cage motor has simple structure, reliable operation, low cost and simple start-up, which is used most. But the power factor is low. InAir separation equipmentThe lower power machines such as the liquid oxygen pump, water pump and blower are all using squirrel cage motors.
The rotor structure of winding motor is more complicated than squirrel cage motor. But it has the characteristics that squirrel cage motor does not have. When starting, the rotor coil is connected with a resistance or a frequency sensitive rheostat, which can reduce the starting current and increase the starting torque. Adjusting the resistance value of the rotor string can also adjust the rotating speed of the motor. Winding motor is used in air compressor and oxygen compressor with higher power.
The stator of the synchronous motor is the same as that of the asynchronous motor, except that the rotor iron core is covered with DC excitation winding, which has two outgoing lines connected to two slide rings, and the magnetic direct current is supplied by the outside to form a constant magnetic pole. The rotating speed of synchronous motor does not change with the change of load. In addition, it has high utilization rate of electric energy, which means high power factor. Synchronous motor is mainly used inAir compressor,Oxygen compressorThis kind of equipment requires constant speed and high power.

DEAR Air Separation Solve YourWhat kinds of types of motors are commonly used in the air separation plant and in what occasions?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts