What should be done when the power supply of the air separation plant of the molecular sieve adsorption purification process is restored after the power failure?

What should be done when the power supply of the air separation plant of the molecular sieve adsorption purification process is restored after the power failure?
Oct 10, 2024
Author: DEAR AST
Question Reply

Molecular sieve adsorption purification processAir separation equipmentWhen the power supply is restored after the power failure, the operation should follow the following steps:
1) judge the possible influence on mechanical equipment such as air compressor when the power is suddenly cut off. If there is no influence, according to the operation specification of the air compressorAir compressorStart-up preparation;
2) check and confirm the switch state of the chain shutdown equipment valve;
3) check and confirm the alarm chain project of the air separation plant. Re-check and confirm the chain control of failure during power failure;
4) start the air compressor and air precooling system according to regulations;
5) start the molecular sieve adsorber according to the regulations. Continue to complete the process before shutdown. If the downtime is long (more than 24 h), the molecular sieve adsorber should recycle for one cycle;
6) according to the length of downtime, the cold end temperature of the main heat exchanger and the main cold liquid level, etc., according to the regulations to determineAir separation equipmentStart the startup procedure.

DEAR Air Separation Solve YourWhat should be done when the power supply of the air separation plant of the molecular sieve adsorption purification process is restored after the power failure?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Generally, the actual cooling capacity of expander is always less than the theoretical cooling capacity. Under the same inlet and outlet pressure and inlet gas temperature, the lower the efficiency of expander, the smaller the unit refrigerant cooling capacity and the smaller the temperature drop efficiency of expander. The efficiency of expander depends on the size of various losses inside the expander. Due to the existence of various losses, the ability of gas to do external work is reduced in varying degrees. To sum up, the losses mainly include the following aspects: 1. When the air flow passes through the work wheel and the deflector, the loss caused by friction and air flow impact on the runner surface is called flow loss. 2. When the impeller is rotating, the friction heat generated by the gas around the wheel disc will increase the temperature of the gas, which is called friction blast loss. 3. When the gas passes through the deflector, the leakage from the gap bet
2025.11.07
The principle and function of molecular sieve purification system in air separation equipment?
2025.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top