Technical maintenance of power equipment includes:
(L) daily inspection and inspection tour by the operation personnel of the power station according to the specified time, route, project and requirements, make use of human senses or simple instruments and meters to test and inspect the equipment, observe, record the running condition of the equipment and the intact condition of the safety facilities, and timely find outAir separation equipmentDefects and hidden dangers, and take corresponding maintenance measures to ensure the normal operation of power equipment.
In daily spot inspection and round inspection, for the new equipment which has just been put into operation, and the equipment which has restored operation after major accidents occur, the equipment operating under severe weather conditions (such as strong wind, thunder, rain, hailstones, snow, frost, fog, etc.) is regarded as the key inspection content. As for the power equipment (such as the power distribution cabinet in the workshop, low-voltage distribution room, etc.) which is under the supervision and control of the personnel on duty, it should be inspected and inspected by professional maintenance personnel. Special inspection tour is needed for some power equipment. For example, the substation should conduct at least one inspection tour of closing lights at night every month, and check whether there is flashover or glow discharge in the running electric circuit and related devices.
(2) regular inspection on the basis of daily maintenance, according to the defects and seasonal requirements of power equipment, regularly check and clean the equipment, add or replace insulation oil and lubricating oil, repair or replace related components, etc. Through regular inspection, we can also confirm or revise the work items and workload that should be completed in the next overhaul.
(3) preventive test (inspection) the purpose of preventive test (inspection) is to check the operational reliability and safety of the power equipment and the power pipeline during the two adjacent planned repairs, and to find hidden dangers in time, prevent accidents. The interval and content of preventive test should be conducted according to the requirements of relevant regulations and instructions.

DEAR Air Separation Solve YourWhat are the technical maintenance of power equipment?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The air cooling tower is the core equipment of the air separation precooling system, which is mainly used to cool and wash the high-temperature compressed air discharged from the air compressor, provide qualified low-temperature gas source for subsequent molecular sieve purification and cold box rectification, and ensure the stable operation of the whole unit. The air cooling tower adopts the countercurrent packing heat exchange structure, the tower is filled with high-efficiency packing, and the top is equipped with a spray device and a wire mesh demister. During operation, the high-temperature compressed air at 80 to 100 ℃ discharged by the air compressor enters from the bottom of the tower and flows from bottom to top; The cooling water is the normal temperature make-up water and the low-temperature chilled water prepared by the water-cooling tower, which is sprayed from top to bottom from the tower top, and the air and water are fully contacted in reverse for heat exchange. Under t
2026.11.12
Regulation of liquid nitrogen throttle valveThe opening of the liquid nitrogen throttle valve not only affects the reflux ratio of the upper tower, but also affects the reflux ratio of the lower tower. When the opening is increased, the reflux ratio of the upper tower increases, while the reflux ratio of the lower tower decreases, the purity of the nitrogen in the upper tower increases, and the purity of the oxygen enriched night sky in the lower tower increases. However, after the opening is over, the purity of the liquid nitrogen decreases, and the reduction of the reflux ratio of the upper tower is also detrimental to the improvement of the purity of the liquid oxygen. Therefore, an equilibrium point should be found for the opening of the liquid nitrogen throttle valve. We can generally use the purity difference between liquid nitrogen and gas nitrogen to judge whether the opening is appropriate. Generally, the purity of the sprayed liquid nitrogen is equal to that of the upper towe
2026.11.11
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top