What is the effect on the work of the compressor if the oil temperature of the compressor lubricating oil is too high or too low? What measures should be taken?

What is the effect on the work of the compressor if the oil temperature of the compressor lubricating oil is too high or too low? What measures should be taken?
Dec 02, 2022
Author: DEAR AST
Question Reply

The function of lubricating oil is to lubricate the bearing of compressor, reduce friction, take away the heat generated by friction and cool the bearing.
If the oil temperature is too high, the effect of cooling bearing will be bad, which will lead to the rise of bearing temperature; in addition, the increase of oil temperature will also lead to the decrease of viscosity of lubricating oil, which will easily cause the damage of local oil film and the failure of lubrication, reduce the bearing capacity of the bearing, and even cause carbonization of lubricating oil to burn tiles.
If the temperature of oil is too low, the viscosity of oil will increase, which will increase the lubrication friction of oil film and increase the power consumption of bearings. In addition, it will make the oil film thicker and produce machine vibration caused by oil film vibration. Therefore, the inlet oil temperature of lubricating oil should not be lower than 25℃, and the outlet oil temperature should not be higher than 60℃.
The change of oil temperature can be adjusted by the cooling water flow of heater and cooler. When the oil temperature is too low, the oil heater can be started to close or reduce the flow of cooling water; when the oil temperature is too high, the amount of cooling water can be increased. If it still doesn't work, check whether the oil pressure drops, whether the cooler is dirty or blocked, and also check whether the bearing is damaged.

DEAR Air Separation Solve YourWhat is the effect on the work of the compressor if the oil temperature of the compressor lubricating oil is too high or too low? What measures should be taken?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
When the demand for oxygen increases higher than the normal working condition, more liquid oxygen is extracted from the liquid oxygen storage tank, pressurized to the required pressure by the liquid oxygen pump and sent into the main heat exchanger after gasification and reheating, and the liquid oxygen stored in the liquid oxygen storage tank is consumed. At the same time, the flow of low-pressure expander will be reduced, and more cold volume will be recovered by high-pressure nitrogen and the...
2026.09.22
Brief description of the molecular sieve problem The purifier CO₂ suddenly started to run abnormally and suddenly went out of range in liquid air separation plants, the dew point never changed significantly. The dew point did not change significantly. In order to ensure that the other molecular sieve had enough time to regenerate, the time could not be shortened any further. At this point there was a relatively stable situation with no further deterioration. Check the trend graph for a cold bl...
2026.09.21
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top