What safety issues should be paid attention to in the use of low temperature liquid gasification machine?

What safety issues should be paid attention to in the use of low temperature liquid gasification machine?
Apr 04, 2023
Author: DEAR AST
Question Reply

Low temperature of liquid oxygen, liquid nitrogen, liquid argon, etc.Liquid aeratorWidely used in liquid gasification station, direct gas supply or bottle filling. In order to ensure the safe operation of the aerator, safety control points should be set up and the following matters should be paid attention:


1) set the low temperature control interlock point of the low temperature liquid outlet air purifier. Control the gas outlet temperature to 5 ~ 30℃. When the outlet temperature is lower than 0℃, the liquid pump will be cut off automatically and the liquid will be stopped from entering the air purifier. The air purifier without liquid pump will give out sound and light alarm;
2) set air purifier water temperature control interlock point. Control the water temperature at 40 ~ 60℃. When the water temperature is lower than 30℃, the liquid pump will be cut off automatically, and the liquid will stop entering the air purifier;
3) set the pressure control interlocking point of gasification gas outlet, and control the pressure at the set value. When the outlet gas pressure is higher than the set value, it will give out sound and light alarm; if the pressure continues to rise, it will automatically cut off the liquid pump and stop the liquid from entering the gas purifier;
4) safety valves and vent valves should be installed at the two ends of the liquid pump to ensure the safety of misoperation;
5) the matching pressure gauge and safety valve of air purifier should be checked regularly;
6) before using the air purifier heated by water bath, the water in the water tank must be filled and heated to 40 ~ Liquid can only be supplied after 60℃. Before stopping the air purifier, the infusion valve should be cut off first, and then the heating power should be cut off after heating. Water level should be paid attention to frequently during gasification process, and water should be replenished timely;
7) due to the change of flow during the working process, the temperature after gasification will be affected, so the water temperature should be adjusted timely;
8) If the water temperature drops below 30℃, check whether the electric heating pipe is damaged. If necessary, the output flow should be reduced to ensure the temperature after gasification. When the air purifier is found frozen or frosty in the filling pipeline, the filling should be stopped.

DEAR Air Separation Solve YourWhat safety issues should be paid attention to in the use of low temperature liquid gasification machine?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top