Nitrogen making machineCarbon molecular sieve has high requirements on the quality of compressed air, while compressed air contains a large amount of water, certain dust and oil mist, therefore, before the compressed air enters the nitrogen generator, it must be treated with cooling, water removal, oil removal and so on. The purification treatment of compressed air is of vital importance, which should not be ignored! Because the quality of compressed air purification treatment is directly related to the service life of carbon molecules, thus directly related to the long-term effective use of nitrogen generator.
I. Starting steps of Nitrogen generator
1) turn on the power supply of the cold dryer and precool for five minutes.
2) open the air valve that enters the air dryer, and let the compressed air enter the air dryer to remove water, oil and dust.
3) open the air valve entering the nitrogen generation machine, and let the dry clean air enter the nitrogen generation machine.
4) turn on the power supply and emergency switch of the nitrogen generator, and start the unit to enter the working state.
5) wait for 15 minutes, and let the nitrogen generation machine have enough time to produce nitrogen.

II. Stop steps of Nitrogen generator 
1) press the stop switch and power switch on the nitrogen generator.
2) turn off the power switch of the cold dryer.
3) close the air valve entering the nitrogen generator.
4) cut off the main power supply if it is not used for a long time.

III. Others 
1) Please check whether the cold dryer works normally every day, and use the air gun to test whether the water and oil in the air exceed the standard.
2) Please keep the pressure of nitrogen gas cylinder, and do not drain.
3) Please keep the surrounding environment of Nitrogen generator body clean and tidy.

IV. Matters needing attention in the use of nitrogen generator 
1. 220 V power supply is used in the whole nitrogen production system. Please pay attention to the safety of electricity usage. Non-professional personnel should not operate electric appliances or modify circuits without authorization.
2. Before opening the nitrogen generator, the inlet compressed air pressure must be ensured to be above 0.7Mpa, otherwise the efficiency of the nitrogen generator cannot be fully exerted.
3. Confirm that the compressed air processing equipment (freezing or adsorption dryer) must be in the working state and can handle most of the oil, water, dust and impurities in the compressed air.
4. The best choice of the rated exhaust pressure of the air compressor is 0.8-1.0Mpa (at least ≥ 0.75Mpa), and the oil content in the compressed air must be ≤10ppm w/w.
5. Turn on the power supply of the cold dryer before use, and let the cold dryer precool for about 5 minutes, then turn on the nitrogen generator.
6. Maintain and maintain according to the technical requirements of air compressor and cold dryer to ensure air quality. Air compressor and cold dryer must be repaired and maintained at least once a year.
7. Record the use date of each pre-screening program, and replace its filter element regularly.
8. It is better to use copper pipe or stainless steel pipe (followed by galvanized pipe) thread connection or welding for each pipeline outside the nitrogen generation machine.
9. Do not move the electrical devices in the electric control cabinet at will, and do not dismantle the pneumatic pipe valve at will. The adjusted valve of debugging personnel should not rotate at will in case of affecting the purity of nitrogen.
10. Equipped with full-time operation and maintenance management personnel and special training. Equipment appearance should be kept clean and clean, often scrub with wet cloth or neutral soap water.

DEAR Air Separation Solve YourHow to use nitrogen generator correctly?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The deflagration of the oxygen compressor will cause great harm to the safe operation of the air separation equipment and the personal safety of the operators. Each air separation user should attach great importance to the safe operation of the oxygen compressor to prevent the occurrence of the deflagration accident.
2025.05.09
The design of the internal structure of the adsorber: the design of the internal structure of the adsorber includes the determination of the bed layer and various auxiliary structures, such as the design of the upper and lower filter, the guide valve, the pressing mechanism, the gas distribution device and so on. The adsorber can usually be divided into single bed and double bed, and the structure is shown in figure 3. Both the upper and lower vent of the two structures are equipped with filter and gas distributor. The single-layer bed structure is equipped with a screen hole plate and a cylinder compressing device on the molecular sieve adsorber. When the adsorber is working, the cylinder piston generates a lower thrust by differential pressure and compresses the molecular sieve through the screen hole plate, it avoids the phenomena that the molecular sieve is boiling and flowing and the filter screen is damaged due to the excessive airflow, thus prolonging the life of the molecula...
2025.05.08
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top