Why should average pressure be performed when the molecular sieve adsorber is switched:
(1)Molecular sieve adsorberWhen switching, the pressure should be balanced first to ensure the smooth operation of the whole device. When the molecular sieve adsorber is switching, if the pressure is uneven, then in order to fill the inner space of the container, the air flow and pressure of the device will fluctuate suddenly.
(2) In addition, to be put into useMolecular sieve adsorberIf the average pressure is not implemented first, the switch will be subject to the strong impact of the air, making the barrier deformation or even damage. Aluminum glue and molecular sieve also rub and squeeze each other because of the impact. After producing dust particles, they enter the internal channel of the absorbant, causing blocking and reducing the adsorption efficiency. SoMolecular sieve adsorberThe pressure must be balanced before switching.