当前位置: Home / Faq / Biogas purification FAQ /

Construction site safety common sense

Construction site safety common sense
May 16, 2024
Author: DEAR AST
Question Reply

At the installation site of the air separation equipment, we may see a variety of operation methods. For the first time, we may be a bit surprised. If we see more times, we may be accustomed to it. However, many accidents are caused by our negligence and ignorance. Here are some common sense for safe construction, hope it can be helpful:

 

1. Workers must wear safety helmets properly when entering the construction site, because the construction site is often chaotic. Some equipment installation sites, several construction teams are working at the same time, it is impossible to completely guarantee that there are no falling objects.


2. Proper use of personal protective equipment, and carefully implement safety protection measures. When working on high places, cliffs and steep slopes without protective facilities, safety belts must be fastened.


3. It is forbidden to climb scaffolds and safety protection facilities. It is strictly forbidden to ride the hoisting cage to go up or down or to cross the protective facilities.


4. The on-site use of open flames must have approval procedures and fire monitoring personnel equipped with appropriate fire extinguishing equipment. Before leaving work, you must confirm that there are no hidden fire hazards before leaving.


5. Personnel engaged in metal welding (gas cutting) and other operations must be certified to work, and fire prevention measures should be taken during welding and cutting.


6. Smoking is prohibited in the construction area except at the designated site.


While ensuring production progress, we must also pay attention to our own safety. Only by keeping safety in mind at all times, and being in awe of safe operating procedures, can we avoid serious consequences caused by a moment of negligence. Labor creates wealth, security brings happiness!

DEAR Air Separation Solve YourConstruction site safety common senseYou can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top