Author: DEAR AST

Air cooling tower and water cooling tower are key cooling and purification units in air separation equipment. They work together to provide qualified low-temperature and clean air for subsequent air compression, rectification and other processes. The core is to achieve cooling and preliminary removal of impurities through heat exchange through medium contact.
The air cooling tower is mainly used to cool the compressed air. High-temperature compressed air (about 80 ℃) from air compressor enters the bottom of air cooling tower and flows from top to bottom; Normal temperature cooling water is sprayed on the top of the tower and reversely contacts with air from bottom to top. Through heat exchange, the high temperature air transfers heat to the cooling water, and the temperature is reduced to about 30 ℃. At the same time, some water, oil and other impurities in the air are settled with the cooling water to achieve preliminary purification and avoid scaling or blocking of subsequent equipment.
The core of the water cooling tower is the circulating water used for cooling the air cooling tower to maintain the stability of the cooling effect. It adopts the "gas-water heat exchange" mode, uses the waste nitrogen (low temperature, dry) discharged from the air separation system as the cooling medium, enters from the bottom of the water cooling tower, and reversely contacts with the return water of the air cooling tower sprayed at the top of the tower. The waste nitrogen absorbs the heat in the circulating water, and is heated and discharged. The circulating water is cooled to normal temperature and then sent to the air cooling tower for recycling.
The two complement each other: the air cooling tower realizes air cooling by relying on the low-temperature cooling water provided by the water cooling tower, and the water cooling tower realizes circulating water cooling by relying on the cooling capacity of the contaminated nitrogen, so as to jointly ensure the stable and efficient operation of the subsequent processes of the air separation equipment.

DEAR Air Separation Solve YourWhat is the working principle of air cooling tower and water cooling tower of air separation equipment?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top