Oxygen and nitrogen have a certain state under certain conditions. When the temperature reaches the boiling point under certain pressure, they will change from a liquid state to a gaseous state. When the pressure is constant, both oxygen and nitrogen have their fixed boiling points. But the boiling point of a mixture of oxygen and nitrogen is neither equal to the boiling point of oxygen at the same pressure nor the boiling point of nitrogen at the same pressure, but between the two. When the temperature reaches the boiling point of nitrogen, the mixture will not boil, and similarly, when the temperature drops to the condensation temperature of oxygen, the mixture will not condense.

DEAR Air Separation enhances the performance of distillation columns and extensively uses structured fillers in their distillation columns. This type of filler can replace saddle mesh filler θ Mesh ring packing can also replace sieve tray towers. It has high mass transfer efficiency and small resistance drop. It is a preferred internal component for distillation columns in ultra-low pressure process air separation equipment. The Tianjin University ZUPAC PLUS structured packing selected for Deer Air Separation can significantly reduce pressure, improve separation efficiency, and reduce liquid holding capacity. The start-up time of the device has also been significantly reduced.

DEAR Air Separation Solve YourBoiling point of oxygen nitrogen mixture in air separation equipmentYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The liquid air separation plant system uses the cold energy to produce liquid oxygen, liquid nitrogen and liquid argon in an air separation system, including an air compression pre-cooling system, an air purification system, an air separation system and a nitrogen circulation system for liquid air separation plant cold recovery. the nitrogen circulation system for liquid air separation plant cold recovery is placed in a separate cold box from the main cold box of the air separation system. the l...
2026.08.03
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top