What is the working principle of air separation equipment precooling system?

What is the working principle of air separation equipment precooling system?
Feb 28, 2026
Author: DEAR AST

Precooling system of air separation equipment is the key link before raw material air treatment. Its core function is cooling and water removal, which lays a foundation for efficient operation of subsequent purification system, avoids load of absorber due to high temperature air, and ensures stability of low temperature working condition of the whole equipment. The system takes heat exchange cooling and condensate water removal as the core logic, and completes air pretreatment through multiple equipment cooperation.
During operation, the feed air boosted by the compressor enters the air cooling tower for reverse contact and heat exchange with cooling media such as circulating water and chilled water. The temperature of high temperature air drops to 4-10 ℃ after full heat exchange with low temperature medium. Most of the water in the air is condensed and separated out with the decrease of temperature and discharged from the drainage device at the bottom of air cooling tower to realize preliminary dehydration.
The system is equipped with chiller, circulating water pump and measurement and control device: the chiller provides stable cooling capacity to ensure cooling effect; Keep the medium circulation unobstructed by the water pump; The control system monitors the inlet and outlet temperature and liquid level of the air cooling tower in real time, automatically regulates the load and medium flow of the refrigerator, and accurately controls the air temperature and humidity.
The pre-cooled air can stably enter the subsequent purification process after reaching the standard temperature and greatly reducing the water content. The efficient operation of the precooling system can improve the overall processing efficiency and reduce the equipment loss, which is an important guarantee for the continuous and safe operation of the air separation equipment.

DEAR Air Separation Solve YourWhat is the working principle of air separation equipment precooling system?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the main column of the air separation column, the distribution of argon varies with the position of the liquid air inlet. With the increase of liquid air inlet position, the maximum concentration of argon enrichment zone in the stripping section also increases, and the nitrogen content in the distillate can be reduced. However, the argon content in the downstream also increases. In order to ensure the purity of oxygen, more trays are needed under the extraction port of argon fraction. Therefore, in the case of producing argon, the position of liquid air supply E1 should be appropriately increased compared with the case of not producing argon. Some unit is equipped with two liquid air inlet positions to meet the conditions of argon production and non argon production respectively. In the production of argon, in order to improve the extraction rate of argon, the content of argon in oxygen and nitrogen must be reduced. When the content of argon in exhaust nitrogen is more than 0.3%
2026.07.07
Why is dew point commonly used in air separation equipment to indicate the moisture content in the air?
2026.07.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top