How to prevent scaling of cooling system of air separation equipment?

How to prevent scaling of cooling system of air separation equipment?
Nov 24, 2025
Author: DEAR AST

The scaling of cooling system of air separation equipment will seriously affect the operation efficiency and safety of equipment, so effective preventive measures must be taken.
For water quality management, calcium ion, magnesium ion and other impurities in cooling water are the main causes of scaling, and water quality indexes shall be strictly controlled. Check the water quality of the cooling water regularly, and add appropriate water treatment agents according to the test results. They can interfere with the impurity crystallization process and prevent the formation of large scale. At the same time, adjust the dosage according to the change of water quality to ensure the treatment effect.
Optimize the design of cooling water circulation system. Reasonably design the pipeline layout, reduce the dead angle of water flow and avoid the deposition of impurities. Ensure that the water flow velocity is moderate, too slow will make the impurities easy to attach, too fast may accelerate the equipment wear, generally controlled within the appropriate range, to enhance the water flow's ability to scour and carry impurities.
Clean and maintain the cooling system regularly. Develop a scientific and reasonable cleaning plan, and adopt the combination of physical cleaning and chemical cleaning. Physical cleaning such as high-pressure water washing can remove loose dirt on the surface; For chemical cleaning, select proper cleaning agent to dissolve and remove stubborn scale. Rinse thoroughly after cleaning to prevent corrosion to the system caused by residual chemicals.
The above comprehensive measures can effectively prevent scaling of cooling system of air separation equipment and ensure stable and efficient operation of equipment.

DEAR Air Separation Solve YourHow to prevent scaling of cooling system of air separation equipment?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
It should contact with the front and rear processes when the piston compressor is ready to stop, we should pay attention to the following sequence: first, cut off the gas supply slowly. In order to prevent the outlet pressure from rising after the gas supply is cut off, open the vent valve at the same time. For the oxygen compressor, the vent valve should be opened slowly, because excessive opening may produce static electricity and cause fire. Then, stop the motor. After the motor stops, turn off the circulating oil pump, grease injector motor and cooling water valve. However, there are also exception cases. For example, in case of emergency shutdown, in order to save time and prevent the accident from expanding, the power supply can be cut off immediately to stop the compressor with load.
2026.01.28
Why do gas nitrogen and liquid nitrogen coexist at the top of the distillation tower of an air separation plant
2026.01.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top