How to take measures to ensure the normal operation of the cooling system when the air compressor of the air separation equipment generates a large amount of heat during operation?

How to take measures to ensure the normal operation of the cooling system when the air compressor of the air separation equipment generates a large amount of heat during operation?
Nov 03, 2025
Author: DEAR AST

To ensure the normal operation of the cooling system (water pump, radiator, coolant) of the air separation equipment compressor, targeted measures need to be taken from five core links: coolant management, radiator maintenance, water pump inspection, thermostat calibration, and fan and air duct optimization,
1、 Coolant management, ensuring that the liquid level and quality meet the standards, and monitoring the liquid level; Check frequency, at least once a month, after the equipment has cooled down, check the coolant storage tank level to ensure it is between the "MIN" and "max" marks. Quality maintenance, deterioration judgment. If the coolant appears cloudy, discolored, or has an odor, it needs to be replaced in advance to avoid affecting the heat dissipation performance.
2、 Maintenance of radiator, ensuring heat dissipation efficiency, cleaning frequency: once every quarter, use compressed air or water gun (adjusted to low pressure) to clean the back of the radiator, remove dust and debris, and avoid blockage of the radiator fins. Structural inspection, leakage detection, using air pressure method to check whether the radiator pipes and welding parts are loose, whether the upper and lower water chambers are corroded, and promptly repair any problems found.
3、 Check the water pump to ensure normal circulation power, monitor the operating status, conduct noise inspection, and troubleshoot water leakage. Belt maintenance and tightness adjustment.
4、 Calibrate the thermostat and adjust the coolant circulation path.
5、 Optimization of fans and air ducts to enhance heat dissipation efficiency.

DEAR Air Separation Solve YourHow to take measures to ensure the normal operation of the cooling system when the air compressor of the air separation equipment generates a large amount of heat during operation?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What is the enthalpy in the air separation plant?
2026.08.20
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
2026.08.18
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top