How to take measures to ensure the normal operation of the cooling system when the air compressor of the air separation equipment generates a large amount of heat during operation?

How to take measures to ensure the normal operation of the cooling system when the air compressor of the air separation equipment generates a large amount of heat during operation?
Nov 03, 2025
Author: DEAR AST

To ensure the normal operation of the cooling system (water pump, radiator, coolant) of the air separation equipment compressor, targeted measures need to be taken from five core links: coolant management, radiator maintenance, water pump inspection, thermostat calibration, and fan and air duct optimization,
1、 Coolant management, ensuring that the liquid level and quality meet the standards, and monitoring the liquid level; Check frequency, at least once a month, after the equipment has cooled down, check the coolant storage tank level to ensure it is between the "MIN" and "max" marks. Quality maintenance, deterioration judgment. If the coolant appears cloudy, discolored, or has an odor, it needs to be replaced in advance to avoid affecting the heat dissipation performance.
2、 Maintenance of radiator, ensuring heat dissipation efficiency, cleaning frequency: once every quarter, use compressed air or water gun (adjusted to low pressure) to clean the back of the radiator, remove dust and debris, and avoid blockage of the radiator fins. Structural inspection, leakage detection, using air pressure method to check whether the radiator pipes and welding parts are loose, whether the upper and lower water chambers are corroded, and promptly repair any problems found.
3、 Check the water pump to ensure normal circulation power, monitor the operating status, conduct noise inspection, and troubleshoot water leakage. Belt maintenance and tightness adjustment.
4、 Calibrate the thermostat and adjust the coolant circulation path.
5、 Optimization of fans and air ducts to enhance heat dissipation efficiency.

DEAR Air Separation Solve YourHow to take measures to ensure the normal operation of the cooling system when the air compressor of the air separation equipment generates a large amount of heat during operation?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top