What are the signs of excessive carbon dioxide and water in the air after the molecular sieve adsorber of the air separation equipment? What is the reason?

What are the signs of excessive carbon dioxide and water in the air after the molecular sieve adsorber of the air separation equipment? What is the reason?
Apr 28, 2024
Author: DEAR AST

The signs of excessive carbon dioxide and water in the air after the molecular sieve adsorber are:
(1) At the end of the use cycle of the molecular sieve adsorber, the carbon dioxide and water content increase rapidly, and the alarm values of the testing instrument should be monitored at all times;
(2) The carbon dioxide and water in the main heat exchanger have a freezing phenomenon, and the temperature difference at the hot end increases.
The cause is:
(1) If the molecular sieve is used for too long, the adsorption performance will decrease;
(2) Incomplete regeneration of molecular sieve, leakage of regeneration heater, humid regeneration gas or excessive moisture in the air affecting the adsorption of carbon dioxide;
(3) The uneven bed of the horizontal molecular sieve adsorber causes a short circuit in the airflow;
(4) The bed of the vertical molecular sieve adsorber has gaps, causing a short circuit in the airflow.
DEAR Air Separation has long-term experience in production, design, technology, and equipment manufacturing in the air separation industry. It has detailed research and regulations on equipment requirements and safety precautions to ensure the safe operation of air separation equipment.

DEAR Air Separation Solve YourWhat are the signs of excessive carbon dioxide and water in the air after the molecular sieve adsorber of the air separation equipment? What is the reason?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Generally, the actual cooling capacity of expander is always less than the theoretical cooling capacity. Under the same inlet and outlet pressure and inlet gas temperature, the lower the efficiency of expander, the smaller the unit refrigerant cooling capacity and the smaller the temperature drop efficiency of expander. The efficiency of expander depends on the size of various losses inside the expander. Due to the existence of various losses, the ability of gas to do external work is reduced in varying degrees. To sum up, the losses mainly include the following aspects: 1. When the air flow passes through the work wheel and the deflector, the loss caused by friction and air flow impact on the runner surface is called flow loss. 2. When the impeller is rotating, the friction heat generated by the gas around the wheel disc will increase the temperature of the gas, which is called friction blast loss. 3. When the gas passes through the deflector, the leakage from the gap bet
2025.11.07
The principle and function of molecular sieve purification system in air separation equipment?
2025.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top