What are the reasons why the rated power and pressure of the low-temperature liquid pump in the air separation equipment cannot be reached, and how to deal with them?

What are the reasons why the rated power and pressure of the low-temperature liquid pump in the air separation equipment cannot be reached, and how to deal with them?
Feb 26, 2024
Author: DEAR AST

The reasons why the rated power and pressure of the low-temperature liquid pump cannot be reached are as follows:

1. Cavitation or binding of the pump;

2. Impeller or volute blockage;

3. The heating before starting the pump is not qualified, and there is moisture inside the pump;

4. Damaged sealing ring and impeller;

5. The pressure after discharging the system is higher than the rated value.

Solution:

1. Improve inlet conditions, clean inlet filters, and ensure complete exhaust;

2. Clean up the blocked parts;

3. Remove moisture from dry and heated gas;

4. Replace the damaged parts;

5. Check the characteristic curves of the pump and discharge system, and improve the system pipelines.

The production technology of DEAR air separation equipment is mature and standardized, with strict technical control, and the equipment is safe and high-quality,

Ensure production safety, operation and maintenance, stable and efficient operation.

DEAR Air Separation Solve YourWhat are the reasons why the rated power and pressure of the low-temperature liquid pump in the air separation equipment cannot be reached, and how to deal with them?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
According to the daily water quality analysis and laboratory results, supplement the discharge water and control the dosing amount to make it reach the required data index. When the turbidity is >20mgL, increase the amount of drainage water, increase the flow of side filtration, and supplement clean water. According to the current situation of the circulating water system, try to increase the concentration multiple operation to save water and medicine. If the concentration multiplier is g...
2026.09.04
Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.   After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.   The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. Af...
2026.09.03
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top