What are the reasons why the rated power and pressure of the low-temperature liquid pump in the air separation equipment cannot be reached, and how to deal with them?

What are the reasons why the rated power and pressure of the low-temperature liquid pump in the air separation equipment cannot be reached, and how to deal with them?
Feb 26, 2024
Author: DEAR AST

The reasons why the rated power and pressure of the low-temperature liquid pump cannot be reached are as follows:

1. Cavitation or binding of the pump;

2. Impeller or volute blockage;

3. The heating before starting the pump is not qualified, and there is moisture inside the pump;

4. Damaged sealing ring and impeller;

5. The pressure after discharging the system is higher than the rated value.

Solution:

1. Improve inlet conditions, clean inlet filters, and ensure complete exhaust;

2. Clean up the blocked parts;

3. Remove moisture from dry and heated gas;

4. Replace the damaged parts;

5. Check the characteristic curves of the pump and discharge system, and improve the system pipelines.

The production technology of DEAR air separation equipment is mature and standardized, with strict technical control, and the equipment is safe and high-quality,

Ensure production safety, operation and maintenance, stable and efficient operation.

DEAR Air Separation Solve YourWhat are the reasons why the rated power and pressure of the low-temperature liquid pump in the air separation equipment cannot be reached, and how to deal with them?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
It should contact with the front and rear processes when the piston compressor is ready to stop, we should pay attention to the following sequence: first, cut off the gas supply slowly. In order to prevent the outlet pressure from rising after the gas supply is cut off, open the vent valve at the same time. For the oxygen compressor, the vent valve should be opened slowly, because excessive opening may produce static electricity and cause fire. Then, stop the motor. After the motor stops, turn off the circulating oil pump, grease injector motor and cooling water valve. However, there are also exception cases. For example, in case of emergency shutdown, in order to save time and prevent the accident from expanding, the power supply can be cut off immediately to stop the compressor with load.
2026.01.28
Why do gas nitrogen and liquid nitrogen coexist at the top of the distillation tower of an air separation plant
2026.01.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top