What are the reasons why the rated power and pressure of the low-temperature liquid pump in the air separation equipment cannot be reached, and how to deal with them?

What are the reasons why the rated power and pressure of the low-temperature liquid pump in the air separation equipment cannot be reached, and how to deal with them?
Feb 26, 2024
Author: DEAR AST

The reasons why the rated power and pressure of the low-temperature liquid pump cannot be reached are as follows:

1. Cavitation or binding of the pump;

2. Impeller or volute blockage;

3. The heating before starting the pump is not qualified, and there is moisture inside the pump;

4. Damaged sealing ring and impeller;

5. The pressure after discharging the system is higher than the rated value.

Solution:

1. Improve inlet conditions, clean inlet filters, and ensure complete exhaust;

2. Clean up the blocked parts;

3. Remove moisture from dry and heated gas;

4. Replace the damaged parts;

5. Check the characteristic curves of the pump and discharge system, and improve the system pipelines.

The production technology of DEAR air separation equipment is mature and standardized, with strict technical control, and the equipment is safe and high-quality,

Ensure production safety, operation and maintenance, stable and efficient operation.

DEAR Air Separation Solve YourWhat are the reasons why the rated power and pressure of the low-temperature liquid pump in the air separation equipment cannot be reached, and how to deal with them?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The liqued air separation plant cooling capacity is cooled between the air compressor and the nitrogen compressor, resulting in a significant reduction in energy consumption and a 50% saving in energy consumption. At the same time the introduction of liqued air separation plant cold capacity eliminates the chiller, expander, but increases the cold balance of the liquefier, in the heat transfer calculation is more difficult in low temperature conditions, the performance of the fluid changes more ...
2026.04.09
When the air separation unit is in normal operation, the liquid flows down and can only flow on the tray and flow to the lower tray through the overflow bucket because the supporting force of the rising steam prevents the liquid from flowing down from the small hole of the tray. After shutdown, due to the interruption of rising gas flow, the liquid on the tray can flow from the overflow bucket to the lower tray, and also can flow through the small hole on the tray to the lower tray. This will cause the surface of liquid oxygen and liquid air rise, which may exceed the position of the expansion air outlet pipe, resulting in liquid carrying accident of the expander during restart. Therefore, pay attention to the liquid level position when stopping.
2026.04.08
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top