What should be noted for the operation and maintenance of valves in air separation equipment?

What should be noted for the operation and maintenance of valves in air separation equipment?
Dec 22, 2023
Author: DEAR AST

Operation and maintenance of valves in air separation equipment:

1、 Low temperature valves, valves on oxygen pipelines, and valves in contact with oxygen media must be free of oil, grease, and any other impurities. When using, maintaining, and repairing these valves, special attention should be paid to ensuring that they are not contaminated with flammable materials such as oil, grease, and wax. If they come into contact with oil, grease, etc., degreasing treatment should be carried out.

2、 Valve gaskets, sealing packing, and sealing rings must also be oil-free and grease free, and must be made of non combustible materials suitable for oxygen valves. The use of oil immersed wax and combustible materials is strictly prohibited.

3、 The visible surface of the valve stem must be kept clean, and the surface of the valve stem should be regularly coated with a lubricant suitable for oxygen valves.

4、 Check the leakage of the valve.

5、 Low temperature valves, oxygen pipelines, and valves in contact with oxygen media must be cleaned and strictly degreased before installation. The solvents used for cleaning and degreasing must also be free of oil, grease, and any other impurities, and decomposed solutions are not allowed to be used. During valve installation, all solid substances such as slag, iron oxide scale, rust, welding slag, explosives (including grease, preservatives, etc.) must be removed from all valve installation locations.

For detailed management and maintenance requirements for valves and specialized valves, please refer to the relevant valve maintenance manual for details.

DEAR Air Separation Solve YourWhat should be noted for the operation and maintenance of valves in air separation equipment?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The plant operation cycle between two large heating is related to many factors. From an operational point of view, this mainly depends on when the air passage of the main heat exchanger is blocked. The main reason for the blockage is that the moisture and carbon dioxide content in the air entering the unit exceeds the standard, which accumulates and freezes in the main heat exchanger until it is blocked. The abnormal operation of molecular sieve purification system will shorten the operation cycle of the unit. It is mainly caused by the following reasons: 1. The molecular sieve adsorption bed is short circuited. In the process of operation, due to the unstable gas velocity control or switching, the pressure difference between the two tanks is too large, which will affect the bed layer, make the molecular sieve bed uneven and make the bed layer short circuit. In serious cases, the dust screen of the adsorber will break and the molecular sieve powder will enter the heat exchanger c
2026.03.30
What is the oxygen internal compression process
2026.03.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top