Operation and maintenance of valves in air separation equipment:

1、 Low temperature valves, valves on oxygen pipelines, and valves in contact with oxygen media must be free of oil, grease, and any other impurities. When using, maintaining, and repairing these valves, special attention should be paid to ensuring that they are not contaminated with flammable materials such as oil, grease, and wax. If they come into contact with oil, grease, etc., degreasing treatment should be carried out.

2、 Valve gaskets, sealing packing, and sealing rings must also be oil-free and grease free, and must be made of non combustible materials suitable for oxygen valves. The use of oil immersed wax and combustible materials is strictly prohibited.

3、 The visible surface of the valve stem must be kept clean, and the surface of the valve stem should be regularly coated with a lubricant suitable for oxygen valves.

4、 Check the leakage of the valve.

5、 Low temperature valves, oxygen pipelines, and valves in contact with oxygen media must be cleaned and strictly degreased before installation. The solvents used for cleaning and degreasing must also be free of oil, grease, and any other impurities, and decomposed solutions are not allowed to be used. During valve installation, all solid substances such as slag, iron oxide scale, rust, welding slag, explosives (including grease, preservatives, etc.) must be removed from all valve installation locations.

For detailed management and maintenance requirements for valves and specialized valves, please refer to the relevant valve maintenance manual for details.

DEAR Air Separation Solve YourWhat should be noted for the operation and maintenance of valves in air separation equipment?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Generally, the actual cooling capacity of expander is always less than the theoretical cooling capacity. Under the same inlet and outlet pressure and inlet gas temperature, the lower the efficiency of expander, the smaller the unit refrigerant cooling capacity and the smaller the temperature drop efficiency of expander. The efficiency of expander depends on the size of various losses inside the expander. Due to the existence of various losses, the ability of gas to do external work is reduced in varying degrees. To sum up, the losses mainly include the following aspects: 1. When the air flow passes through the work wheel and the deflector, the loss caused by friction and air flow impact on the runner surface is called flow loss. 2. When the impeller is rotating, the friction heat generated by the gas around the wheel disc will increase the temperature of the gas, which is called friction blast loss. 3. When the gas passes through the deflector, the leakage from the gap bet
2025.11.07
The principle and function of molecular sieve purification system in air separation equipment?
2025.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top