The small air separation unit cold box overall repair

The small air separation unit cold box overall repair
May 23, 2022
Author: DEAR AST

The small air separation unit maintenance workers decided to temporarily shut down, export the gas in the tower, two argon pump cold box after picking sand, check the argon pump cold box in the liquid argon and to coarse argon tower valve, the valve after the indentation at the crack opening, low pressure system cold gas leakage. The inspector Personnel wrapped with non-woven cotton, the main tower to maintain a slight positive pressure, for local heating of the liquid argon pump after the main pipe. Open the instrument gas heating valve after the argon pump, remove the check valve spool after the pump and open the outlet valve.

Instrument gas argon pump export check valve, export valve fully open, the crude argon tower stop filling heating to wait for the pipeline to return to room temperature. Because the valve is usually in full open, so the pneumatic valve as a whole removed, replaced by an aluminium elbow and directly connected to the aluminium pipe, the pump main pipe with expansion joint function. Installation of the valve frame in the valve after this service, the valve seat will be fixed. Because the valve is too close to the cold box, it was not possible to add the same pre-valve and post-valve piping restrictions as the pneumatic valve in the main cold box. Two more fixed stands were added to the main pipe after the pump to the crude argon tower, and the pipe shrinkage pulling may be related to this. The small air separation unit continued to accumulate liquid, the tube continued to pre-cool, the small air separation unit all normal, output qualified oxygen and nitrogen for external gas supply.

At the operation and maintenance end, the AI intelligent remote operation and maintenance system of small air separation units, large air separation units and liquid air separation plants, independently developed by  DEAR's air separation team, has made an industry-wide breakthrough in intelligent operation and maintenance, winning awards in various competitions at home and abroad for many times.安钢集团闽源特钢-15000

DEAR Air Separation Solve YourThe small air separation unit cold box overall repairYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The plant operation cycle between two large heating is related to many factors. From an operational point of view, this mainly depends on when the air passage of the main heat exchanger is blocked. The main reason for the blockage is that the moisture and carbon dioxide content in the air entering the unit exceeds the standard, which accumulates and freezes in the main heat exchanger until it is blocked. The abnormal operation of molecular sieve purification system will shorten the operation cycle of the unit. It is mainly caused by the following reasons: 1. The molecular sieve adsorption bed is short circuited. In the process of operation, due to the unstable gas velocity control or switching, the pressure difference between the two tanks is too large, which will affect the bed layer, make the molecular sieve bed uneven and make the bed layer short circuit. In serious cases, the dust screen of the adsorber will break and the molecular sieve powder will enter the heat exchanger c
2026.03.30
What is the oxygen internal compression process
2026.03.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top