当前位置: Home / Faq / Small air separation FAQ /

Operation and maintenance of circulating water system of small air separation units

Operation and maintenance of circulating water system of small air separation units
Apr 11, 2022
Author: DEAR AST

1、Dosing principles

(1) must be accurate, on time, according to the amount of circulating water system in the air separation equipment for dosing

(2) the use of intermittent drainage, should be in the small air separation units circulating water system drainage after dosing

(3) Each time before dosing, the dosing bucket should be rinsed clean before pouring the chemical into the dosing bucket, and the dosing bucket should be rinsed 2~3 times after the chemical is added

(4) If two kinds of algaecides are used, they should be poured alternately, and the time interval between the drugs put into the circulating water system of the air separation equipment should be even

(5) Do not add algaecide and scale and corrosion inhibitor on the same day

(6) Detailed records of daily dosing and discharge replacement

2、Adding chemicals

According to the status quo of circulating water system of small air separation unit and the characteristics of pharmaceuticals, algaecide can be dumped directly into the collecting pool. Scale and corrosion inhibitor dosing formula: in the circulating cooling water collection pool next to the configuration of the dosing tank, the upper part of the dosing tank has a fill pipe, the lower part has a drainage port. Pour the medicine into the dispensing tank, dilute it with supplementary water, and gradually pour it into the collecting pool continuously and evenly with a metering pump.

3、Dosing position

Do not pour the agent into the catch basin near the drainage outlet to avoid the agent being directly discharged before entering the circulating water system. It takes time for the agent to mix well in the pool. Do not dump the agent close to the inlet of one of the pumps as this will result in an uneven distribution of the agent concentration.

Dear Air separation employs dozens of experts and engineers in machine and vessel equipment manufacturing and inspection to ensure the reliability of equipment manufacturing. At present, our company has set up joint research and exchange mechanisms with domestic universities in big data ai algorithm, apc advanced control system, intelligent manufacturing, intelligent operation and maintenance, engineering structural science, nano-sensing field, material science, etc., which has truly become a technology development institution combining academics and production in the air separation industry.

梅花项目1

DEAR Air Separation Solve YourOperation and maintenance of circulating water system of small air separation unitsYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts