Interpretation of nitrogen cycle working condition of liquid air separation plant

Interpretation of nitrogen cycle working condition of liquid air separation plant
Sep 22, 2026
Author: DEAR AST

When the demand for oxygen increases higher than the normal working condition, more liquid oxygen is extracted from the liquid oxygen storage tank, pressurized to the required pressure by the liquid oxygen pump and sent into the main heat exchanger after gasification and reheating, and the liquid oxygen stored in the liquid oxygen storage tank is consumed. At the same time, the flow of low-pressure expander will be reduced, and more cold volume will be recovered by high-pressure nitrogen and then throttled into the pressure tower, and the increased liquid nitrogen will be pumped out from the top of the pressure tower and sent to the liquid nitrogen storage tank through the low-pressure tower kettle. When the oxygen demand decreases below the normal working condition, less liquid oxygen is extracted from the liquid oxygen storage tank, pressurized by the liquid oxygen pump to the required pressure and sent to the main heat exchanger after gasification and reheating, and the excess liquid oxygen is stored in the liquid oxygen tank. At the same time, the flow of low-pressure expander will increase, the cold volume recovered by high-pressure nitrogen will be reduced, and the amount of liquid nitrogen sent to the low-pressure tower will be reduced, and the liquid nitrogen needs to be replenished from the storage tank to the low-pressure tower by the liquid nitrogen pump.

Dear Air Separation has designed liquid air separation plant to meet the needs of our customers according to the different working conditions they require.江苏-善俊

DEAR Air Separation Solve YourInterpretation of nitrogen cycle working condition of liquid air separation plantYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top