当前位置: Home / Faq / Small air separation FAQ /

How to arrange the high-pressure steam main of the small air separation unit?

How to arrange the high-pressure steam main of the small air separation unit?
Nov 13, 2025
Author: DEAR AST

Small air separation unit for turbine high-pressure steam piping materials are selected according to the pipeline level, design temperature, design pressure and special requirements of the medium and other design conditions, as well as the corrosion resistance of the material, processing performance, welding performance and economic rationality.

High-pressure steam main usually laid out on the corridor of small air separation unit, in order to facilitate the pipeline blowing and warming as well as the smooth discharge of condensate in the process of device parking, and to avoid water strikes, which affects the life of the pipeline and device safety. Steam pipeline laying should be set up not less than 0.002 slope, the direction should be consistent with the direction of steam flow, the low point set to drain the liquid. The design pressure and design temperature of the pipeline is high, high-pressure steam pipeline can be changed by the pipeline itself to meet the requirements of natural compensation, commonly used methods are set up "π" type or "L" type compensator, in general, high-pressure steam pipeline should be every 50m Set up a "π" type compensator. If the installation space is limited, you can also use cold tight or a combination of the two to meet the requirements of pipeline flexibility. For small air separation unit, steam piping should be arranged with low-temperature piping (liquid nitrogen, liquid oxygen) and flammable, explosive (oxygen) piping, electrical and instrumentation bridges staggered layout.

In the design process, Dear Air Separation takes into account the process, piping and stress professional process, so that the safety and economy of piping design can reach perfect unity and ensure the stable and long operation of small air separation unit.

山东临沂钢铁集团(三德)16000

DEAR Air Separation Solve YourHow to arrange the high-pressure steam main of the small air separation unit?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top