Causes of reduced efficiency of piston expanders in small air separation unit

Causes of reduced efficiency of piston expanders in small air separation unit
Jan 11, 2022
Author: DEAR AST

The ratio of the actual expansion refrigeration capacity of the expander to the theoretical isentropic expansion refrigeration capacity is the efficiency of the expander. In small air separation unit operation, the efficiency of the expander is generally reduced for the following reasons: poor cooling, the outside world has more heat transfer, pay attention to keep the insulation material dry; inlet and exhaust valves are not closed, exhaust valve seat pressure sleeve top wire is too loose or inlet and exhaust valve rod at the seal is not tight, etc. caused by gas leakage; inlet and exhaust valve opening and closing lag, too much resistance or too much friction heat will cause the piston expander efficiency is reduced.

Dear Air Separation liquid air separation plant and small air separation unit team provides quality service to avoid efficiency degradation of piston expanders and to provide a long-term satisfactory gas supply to our customers.

旋转-DSC03535

 

Dear air separation technical team of experienced experts and professional engineering designers, to provide users with international standards, national standards and industry standards of engineering design, including preliminary design, construction drawings design.

DEAR Air Separation Solve YourCauses of reduced efficiency of piston expanders in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What are the requirements for the design of piping in the cold box of liquid air separation plant? The design of piping in the cold box ofiquid air separation plant is complex and troublesome, and each pipeline has its own process requirements. As one of the most complex components in the cold box of air separation equipment, low temperature piping is the key to ensure the stable and safe operation of small air separation unit. A set of air separation equipment in the cold / hot end of the plat...
2025.05.15
1. Before hoisting, check and confirm whether the crane body, crane legs, lifting rigging and wire rope meet the safety requirements and hoisting conditions. 2. The hanging points of hoisting facilities shall be confirmed to prevent deviation and inclination; steel wire rope or sling shall be used for protection of edges and corners; sling and U-ring shall be used for lifting objects. 3. The commander shall use inter-phone for command, and special personnel shall be assigned for command, and the personnel shall stand at the position where the lifting object can be fully observed; warning isolation shall be set up in the hoisting area, and no one shall stand under the lifting object. 4. For large-scale hoisting, the hoisting safety scheme shall be formulated in combination with the company's special operation system.
2025.05.14
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top