Causes of reduced efficiency of piston expanders in small air separation unit

Causes of reduced efficiency of piston expanders in small air separation unit
Sep 23, 2025
Author: DEAR AST

The ratio of the actual expansion refrigeration capacity of the expander to the theoretical isentropic expansion refrigeration capacity is the efficiency of the expander. In small air separation unit operation, the efficiency of the expander is generally reduced for the following reasons: poor cooling, the outside world has more heat transfer, pay attention to keep the insulation material dry; inlet and exhaust valves are not closed, exhaust valve seat pressure sleeve top wire is too loose or inlet and exhaust valve rod at the seal is not tight, etc. caused by gas leakage; inlet and exhaust valve opening and closing lag, too much resistance or too much friction heat will cause the piston expander efficiency is reduced.

Dear Air Separation liquid air separation plant and small air separation unit team provides quality service to avoid efficiency degradation of piston expanders and to provide a long-term satisfactory gas supply to our customers.

旋转-DSC03535

 

Dear air separation technical team of experienced experts and professional engineering designers, to provide users with international standards, national standards and industry standards of engineering design, including preliminary design, construction drawings design.

DEAR Air Separation Solve YourCauses of reduced efficiency of piston expanders in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The main measures taken for the design of oxygen piping in small air separation unit. 1、The piping material of the high-pressure oxygen gas pipeline is made of stainless steel to reduce the possibility of iron oxidation and combustion under intense working conditions. 2、Partial commercial flow rate piping using copper brocade alloy (Monel); 3, the use of different conditions of the pipeline proposed different degreasing and cleanliness requirements in the selection of Tong expansion joint for...
2026.08.06
According to the specification and smelting level of converter, the total oxygen consumption of steel can be calculated and converted to the oxygen consumption of each hour. The low and peak oxygen consumption is balanced by ball irrigation or liquid vaporization. The gas pressure of peripheral comprehensive pipe network is higher than the pressure of final gas consumption point. It is sent to the user thro...
2026.08.05
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top