Causes of reduced efficiency of piston expanders in small air separation unit

Causes of reduced efficiency of piston expanders in small air separation unit
Sep 23, 2025
Author: DEAR AST

The ratio of the actual expansion refrigeration capacity of the expander to the theoretical isentropic expansion refrigeration capacity is the efficiency of the expander. In small air separation unit operation, the efficiency of the expander is generally reduced for the following reasons: poor cooling, the outside world has more heat transfer, pay attention to keep the insulation material dry; inlet and exhaust valves are not closed, exhaust valve seat pressure sleeve top wire is too loose or inlet and exhaust valve rod at the seal is not tight, etc. caused by gas leakage; inlet and exhaust valve opening and closing lag, too much resistance or too much friction heat will cause the piston expander efficiency is reduced.

Dear Air Separation liquid air separation plant and small air separation unit team provides quality service to avoid efficiency degradation of piston expanders and to provide a long-term satisfactory gas supply to our customers.

旋转-DSC03535

 

Dear air separation technical team of experienced experts and professional engineering designers, to provide users with international standards, national standards and industry standards of engineering design, including preliminary design, construction drawings design.

DEAR Air Separation Solve YourCauses of reduced efficiency of piston expanders in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What are the causes of icing on the outside of the incubator of air separation unit?
2026.07.16
When the amount of treated air increases, the rising steam in the distillation column will increase, and the amount of liquid to be condensed in the main cooler will increase accordingly, so it has no effect on the reflux ratio in the column. The purity of oxygen and nitrogen remained unchanged in a certain range with the increase of gas volume, and the output increased proportionally with the increase of gas volume. However, with the increase of the amount of condensate in the main cooler, the heat load of the main cooler increases. When the heat transfer area is insufficient, the temperature difference of the main cooler will inevitably expand, and the pressure of the lower column will increase accordingly. At the same time, with the increase of gas velocity in the column, the amount of downflow liquid increases, and the liquid layer on the tray thickens, which increases the resistance of the tray and the pressure of the upper and lower columns. This will adversely affect the sepa
2026.07.15
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top