当前位置: Home / Faq / Small air separation FAQ /

The principle of gas throttling in small air separation unit

The principle of gas throttling in small air separation unit
May 20, 2025
Author: DEAR AST

The throttling of gases is a process of equal enthalpy, i.e. throttling is simply a transformation between the internal energy of the gas and the work of propulsion, which includes internal potential energy and internal kinetic energy, while the temperature of the gas is only related to internal kinetic energy. The pressure of a gas is reduced after throttling, its mass volume increases and its internal potential energy always increases. When the flow energy becomes larger, the temperature of the gas decreases, when the flow energy decreases, its absolute value is greater than the increase of the internal potential energy, the temperature of the gas increases when it is throttled.

The intelligent production workshop and production equipment and ancillary facilities of Dear Air Separation small air separation unit and large air separation plant serve as the production base of the Technology Centre, giving priority to the arrangement of research and development production to ensure the smooth implementation of scientific research projects and issues and to promote the rapid, sustainable and coordinated development of the company.

16

DEAR Air Separation Solve YourThe principle of gas throttling in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
What are the reasons why the oxygen production of air separation equipment cannot meet the target
2026.07.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top