The change of the middle temperature is the result of many factors, and after taking measures to adjust it, it will change other related working conditions. Therefore, the adjustment of the middle temperature of the cold accumulator (or switching heat exchanger) should have an overall concept to prevent isolated and one-sided views. We should make a comprehensive analysis of the influencing factors, grasp the main contradictions and take effective measures.DEAR Biogas purification unit.When acetylene or hydrocarbons accumulate in the local area of the main cooling system, explosion may occur under certain conditions. When this kind of slight explosion occurs, there is no external response and no sound, so it is often imperceptible at first. Only when the oxygen purity changes automatically and cannot be adjusted, can this happen.DEAR Biogas purification unit.During the charging process, some molecules (including oxygen and nitrogen molecules) are adsorbed, and the corresponding adsorption heat is carried out by air when it is used. In addition, when the adsorber was first used, the adsorption capacity of molecular sieve was large, so the temperature increased significantly, which was not due to incomplete cold blowing.
DEAR Biogas purification unit.During the regeneration of Molecular Sieve Purifier, the outlet temperature of nitrogen will continue to rise at the beginning of the cold blowing stage, forming a peak value. However, there are two or three peaks in the cold blowing curve of some adsorbers, or the whole peak is relatively flat and the peak is not obvious.The boiling point is the saturation temperature at the same pressure. They have the same meaning, but different views. The coexistence of gas and liquid is called saturation state. If the saturated steam is heated continuously, the temperature of the steam will rise. If the saturated temperature is exceeded, it is called superheated steam.DEAR Biogas purification unit.Machinery industry, mainly used for metal cutting and welding. Oxygen is used as combustion supporting agent of acetylene to produce high temperature flame and melt metal. In national defense industry, liquid oxygen is often used as the combustion supporting agent of rocket. The combustible material soaked in liquid oxygen has strong explosiveness and can be used to make liquid oxygen explosive. In addition, in the medical sector, oxygen is also an indispensable material for first aid and adjuvant treatment of patients. Therefore, oxygen production is an indispensable part of the national economy.
Test the purity of the gas escaping from the cold box. When nitrogen or liquid nitrogen leaks, the volume fraction of nitrogen in cold air can reach more than 80%; when oxygen or liquid oxygen leaks, the volume fraction of oxygen can be significantly increased.DEAR Biogas purification unit.When the purity of oxygen changes by 0.1%, the oxygen content in argon fraction will change by 0.8% ~ 1%. The argon content in argon fraction decreases with the increase of oxygen purity. The change of argon fraction directly affects the argon fraction entering the crude argon column. The higher the oxygen content in the argon fraction, the more the argon fraction entering the crude argon column. On the contrary, there will be less.DEAR Biogas purification unit.The common cases of water inflow into the accumulator (or switching heat exchanger) are as follows: the automatic water level regulation system of the air cooling tower of the nitrogen water precooling system fails, which makes the water level too high. Or improper operation, such as unreasonable start-up of air cooling tower or sudden drop of air separation tower pressure, resulting in a large number of water inflow accidents.

DEAR Air Separation Solve YourHow does the DEAR Biogas purification unit plate and fin heat exchanger achieve heat transfer between several fluids?You can also learn about otherAir separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What are the safety measures for active prevention of condensing evaporators?
2024.04.19
Internal compression air separation process is a process form in which liquid products are pressurized by liquid pump in the cold box, and then sent out of the cold box after reheating by high-pressure heat exchanger. The working pressure of internal compression process generally exceeds the critical point of oxygen and nitrogen. Heat transfer of liquid in supercritical state is a major feature of internal compression process. In the distillation process, due to the difference of product types and acquisition methods, there is a big difference between the material import and export of internal equipment and external compression process. In the internal compressed air separation process, the pressure of oxygen is not limited, the maximum output of nitrogen can reach 2.8 times of that of oxygen, and the extraction rate of argon can reach about 85%. The internal compression air separation process is generally composed of internal compression system, air precooling system, molecular sie
2024.04.18
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top