Why can't the DEAR Biogas purification unit argon fraction extraction port be located at the site with the highest hydrogen content?

Why can't the DEAR Biogas purification unit argon fraction extraction port be located at the site with the highest hydrogen content?
Oct 08, 2023
Author: DEAR AST

DEAR Biogas purification unit.Water is sprayed from the top of the tower to contact and mix with the air to cool the air. A plurality of cross flow sieve plates or fillers are arranged in the air cooling tower to increase the gas-liquid contact area. In order to separate the water, a water capture layer is set on the top of the tower. When the air flow rate in the air cooling tower is too fast, the water carrying or spraying amount is too much, and the water level automatic regulation fails, the water inflow accident of Molecular Sieve Purifier will occur.After cold blowing, the temperature decreases and a flat head peak appears. The longer the curve distance of the flat head peak is, the more water enters into the molecular sieve. In order to prevent the water inflow accident of Molecular Sieve Purifier, attention should be paid to the operation: the air cooling tower should be operated according to the operating procedures, first the gas is injected, and then the water is injected after the pressure rises and stabilizes; the gas volume should not be increased or reduced suddenly;
DEAR Biogas purification unit.In fact, it is difficult to achieve isothermal compression in the compression process of air in the compressor. The temperature after compression is often higher than the ambient temperature when the air is inhaled. The enthalpy value H ′ 2 of the compressed gas may also be higher than the enthalpy value H 2 before compression. However, after throttling by the throttle valve, the temperature will still decrease and the enthalpy will remain unchanged.DEAR Biogas purification unit.Due to these reasons, the temperature difference at the hot end increases, which will stabilize to a certain extent and will not continue to increase. The increase of the pressure difference before and after the heat exchanger is not necessarily due to the freezing of the heat exchanger. Because the molecular sieve in the purifier is broken, or the service cycle is too long, the powder filter at the outlet pipe is blocked, or the valve of the pipeline is too small, the pressure difference before and after the heat exchanger will increase.
For the air separation unit with liquid air subcooler, part of the liquid in the lower tower and main cooler should be drained before starting to prevent the liquid air subcooler from blocking; when the temperature of the cold end reaches - 150 ℃, the circulating flow should be reduced as far as possible to prevent the circulation channel from being blocked by carbon dioxide;Incomplete heat exchange loss Q2 (or Q2). The cooling capacity of low temperature gas is recovered by each heat exchanger in the device. Ideally, the low temperature backflow gas leaving the unit should be reheated to the same temperature as the positive flow gas entering the unit. That is to say, only when the temperature difference at the hot end reaches zero can all the cold energy be recovered. However, heat can only be transferred from high-temperature objects to low-temperature objects. In order to transfer heat from high temperature material to low temperature material in heat exchanger, there must be temperature difference. The temperature difference △ t at the hot end reflects that the temperature of the low temperature gas in the unit is lower than that of the air entering the unit, that is, the cooling capacity cannot be fully recovered, and the cooling capacity loss is called "incomplete heat exchange loss". It is proportional to the temperature difference.
DEAR Biogas purification unit.The central air extraction port of each accumulator in the central air extraction process of the accumulator enters the automatic valve box of the central air extraction through the central air extraction valve. When one of the cool accumulators in each pair flows with positive air, part of the air is extracted from the middle part, and then converges to the CO2 adsorber through the regulating-7 valve.In order to have a preliminary judgment on the leakage position and leakage before shutdown for maintenance, and to shorten the shutdown time, many units have explored some effective methods in practice.DEAR Biogas purification unit.Carbon dioxide precipitation stage. In this stage, only the switching heat exchanger is cryogenic to freeze the carbon dioxide in the heat exchanger, which is carried out by the low-pressure backflow gas until the cold end temperature reaches - 170 ℃; in the fourth stage, the purified low-temperature gas is used to further cool other equipment until liquid accumulates in the tower, and then the distillation condition is further adjusted.

DEAR Air Separation Solve YourWhy can't the DEAR Biogas purification unit argon fraction extraction port be located at the site with the highest hydrogen content?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In medium and large air separation plants, the purification system is an important part when separating oxygen, nitrogen and argon from air. The purification system commonly uses molecular sieve adsorbent to adsorb moisture, carbon dioxide, hydrocarbons, etc. in the air. The molecular sieve purification system plays an important role in the air separation equipment process to ensure safety. The molecular sieve purification system is generally composed of adsorber, electric heater, pipeline, val...
2025.12.12
When the exhaust temperature of the piston compressor is higher than the design value, the most direct impact is that the lubricating oil is carbonized, which leads to the compressor parts burned out because of not getting good lubrication. If the temperature of the compressor is too high during actual operation, the cause should be analyzed in time and corresponding preventive measures should be taken. The following methods can be used for reference in practice. 1. Reducing the inlet air temperature can directly reduce the exhaust temperature. Check the intercooler to ensure the cooling effect of the intercooler. 2. The installation of the valve and the selection of the spring should be standardized to ensure the normal operation of the valve and minimize the loss of inlet and outlet pressure. 3. Strengthen the cooling of cylinder to ensure the normal compression process index. 4. Internal leakage is the main reason for the increase of exhaust temperature. 5.For multist
2025.12.11
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top