How should the DEAR Air separation unit be operated during the liquid oxygen build-up phase in order to accelerate the rise in liquid level?

How should the DEAR Air separation unit be operated during the liquid oxygen build-up phase in order to accelerate the rise in liquid level?
Aug 02, 2021
Author: DEAR AST

DEAR Air separation unit.Copper pipe or stainless steel pipe shall be used at the front and back of valve, elbow, reducer tee, etc.; straight pipe section with diameter greater than 5 times of elbow diameter shall be used at the front and back of elbow; non combustible non cotton asbestos, polytetrafluoroethylene, annealed copper sheet, annealed aluminum sheet, etc. shall be used for packing and flange gasket;DEAR Air separation unit.The corresponding model of the equipment matched with the air separation unit has also been compiled. For example, the model of fractionator: fon-6000 / 13000 means: f-fractionator: on oxygen and nitrogen products; 6000 - oxygen production, m3 / h; 13000 - nitrogen production, m3 / h. Model of liquefaction equipment: ypon -- 200 / 300 means y-liquefaction unit; p-expander; on oxygen nitrogen product; 200 liquid oxygen output L / h; 300 liquid nitrogen output L / h.When extracting rare gas, the distillate gas or liquid containing the rare gas must be extracted from the relevant parts of the distillation column, and then returned to the distillation column after separation. Some need to extract liquid air, liquid nitrogen or medium pressure gas as the cold or heat source of additional equipment.
DEAR Air separation unit.1m3 air with pressure of 0.6MPa is compressed by air with pressure of 0.1MPa and volume of 6m3. The moisture content in 1m3 air also increased to 6 times, that is 6 × 30.3 (g / m3) = 181.8g/m3. If the temperature remains unchanged, the air can only hold 30.3g/m3 of water, then five sixths of the water will be released. With the increase of pressure, the more water is precipitated; the better the cooling effect is, the more water is precipitated.The purpose of purging after heating the fractionator is to remove the mechanical impurities in pipes and vessels. The blowing out steps are as follows: the preparation before blowing out: close the main inlet valve of heating air and all heating valves, open the blowing out valve of oil-water separator of purifier at the same time, loosen the ejector rods of inlet and outlet valves of expander, close the on-6 valve, pull open the stem of joint-1 valve, open the blowing-1 valve, blowing-2 valve and high pressure gauge valve, and close the blowing out valve of oil-water separator of purifier;
DEAR Air separation unit.The chiller uses the artificial method, depending on the consumption of energy (work or heat), and constantly takes away heat from the cooled material, so as to achieve the process of getting lower than the ambient temperature. At present, the most commonly used refrigerator is the compression refrigerator, which uses substances with low boiling point (ammonia, freon, etc.) as the working medium, called "refrigerant".DEAR Air separation unit.Whether the cold insulation material in the dead corner of the cold insulation box is full; whether the cold insulation material sinks after the equipment is running, causing the upper part to have a gap. The greater influence is whether the cold insulation materials keep dry. Because the thermal conductivity of dry pearlite is only 0.03-0.04w / (m ·℃), the thermal conductivity of water is 15-20 times of that of ice and 60 times of that of ice.DEAR Air separation unit.The liquefying temperature of neon and helium is very low. Under normal pressure, the liquefying temperature of neon and helium is 27.26k and 4.21k respectively. Neon is very inert and liquid neon is very safe as the coolant of low temperature laboratory. At the temperature of liquid helium, the conductor will lose its resistance, and there is no loss when the current passes through, forming "superconductivity", which can be made into a superconducting motor. Therefore, with the development of ultra-low temperature technology, liquid helium will play an increasingly important role.

DEAR Air Separation Solve YourHow should the DEAR Air separation unit be operated during the liquid oxygen build-up phase in order to accelerate the rise in liquid level?You can also learn about otherAir separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top