液体管道安全阀保护设置建议

液体管道安全阀保护设置建议
Mar 15, 2021
Author: DEAR AST

The company has several sets of liquid discharge pipeline, pump suction pipeline safety valve selection, in the actual operation process, there is a widespread overpressure unloading. At present, the operation technology of air separation is generally mature, and the operation standard of liquid gasification is the same. The problem reflected by the users does not exist in operation, but the safety valve always fails. The old air separation units used to have liquid oxygen and liquid argon pipeline, equipped with safety valves of liquid oxygen 0.22 MPA and liquid argon 0.28 MPA, are generally installed on the second floor platform, which is no problem. For safety reasons, there are safety valves between the two valves in the present liquid gasification system, which is much more than before. The recent operation of several sets of equipment is basically the same as before. Before the pump, the configuration of safety valve is 0.22MPA, because the configuration of storage tank is also 0.22MPA. In the actual operation process, the pressure and liquid level of the storage tank are not constant, and there is the possibility of overpressure. Therefore, if the take-off pressure is low, the fail is normal.

According to the investigation of most users, the safety valves replaced in the later stage, the conventional low-pressure air separation, and the safety valves from the suction pipe in front of the pump to the cold box are in the range of 0.35-0.4MPA, which is reasonable. The low pressure storage tank can also meet the requirements according to the full pressure of the argon tank of 19.5M and the pressure of several tens KPA. Besides, between the two valves, the pipeline pressure rating is about 40KG, the valve is generally 16KG, and it is not too much to set 5KG protection for the safety valve. As for the equipment, the equipment has its own protection, only considering the pipeline part. Now the general pump suction pressure is 0.05 ~ 0.8MPA, so it is unnecessary to set it very low, which brings trouble to the operation.

DEAR Air Separation Solve Your液体管道安全阀保护设置建议You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What precautions should be taken when designing a complete set of air separation equipment?
2024.11.22
In case of sudden power failure during the operation of small air separation unit, the following steps should be followed:   First, open the vent valve (anti surge valve) of air compressor to prevent the air compressor from surging and causing the air compressor to reverse due to air backflow;   Then check whether the molecular sieve adsorber switch should be interlocked to close, if not, it should be man...
2024.11.21
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top