Matters needing attention in sand cleaning of air separation unit cold box

Matters needing attention in sand cleaning of air separation unit cold box
Jun 26, 2025
Author: DEAR AST
Question Reply

The leakage of unit or pipeline in the cold box needs removal of perlite treatment. Since it is uncertain whether there is a leakage point in the cold box, it will have a certain impact on  removal of perlite. No matter whether the leakage is liquid or air, the sand filling holes at the top should be opened first, so that the residual gas in the cold box can be slowly discharged into the atmosphere. The oxygen content of the gas in the cold box and the pressure indication in the cold box should be strictly monitored in removal of perlite process. In the process of sand stripping, it is particularly important to avoid the formation of sand free area in the middle of the cold box, so as to avoid sand storm caused by the sudden drop of pearlite sand.

DEAR Air Separation Solve YourMatters needing attention in sand cleaning of air separation unit cold boxYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Another part of the nitrogen vaporized in the liquefier is heated up to a certain temperature in the high pressure heat exchanger and pumped out to the low pressure nitrogen press, the nitrogen separated by the gas-liquid separator is also heated up by the high pressure heat exchanger and then goes to the low pressure nitrogen press, compressed to a certain pressure by the low pressure nitrogen press and then back to the high pressure heat exchanger for heat exchange with liquid air separat...
2026.04.17
Special pressure-bearing equipment generally bears internal pressure, that will cause tensile stress inside the shell, which is called working stress. The working stress is directly proportional to the pressure and diameter, and inversely proportional to the vessel wall thickness. The axial stress is half of the circumferential stress. Therefore, for cylindrical vessels, the stress of longitudinal weld is twice that of girth weld. Because the geometric shape of the spherical shell is symmetrical to the spherical center, and the axial stress is equal to the circumferential stress in numerical value. Therefore, the wall thickness of the spherical vessel can be reduced by half as much as that of the cylindrical vessel under the same pressure and diameter.
2026.04.16
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top