Factors affecting oxygen purity in air separation plant

Factors affecting oxygen purity in air separation plant
Sep 30, 2024
Author: DEAR AST
Question Reply

In the air separation plant, the purity of oxygen is mainly determined by the working conditions of the distillation column at the upper and lower parts. In addition, the oxygen content in argon fraction, reflux ratio, number of theoretical trays and separation efficiency will have a direct impact on the purity of oxygen. The following is a brief introduction to the relationship between these factors and oxygen purity.

 

1.The relationship between oxygen content and oxygen purity in argon fraction: the oxygen purity is directly proportional to the oxygen content in argon fraction, that is, the higher the oxygen content in argon fraction, the higher the oxygen purity;

 

2.The effect of the number of theoretical plates at the bottom of the upper column on the oxygen purity: the oxygen purity is directly proportional to the theoretical plate number at the lower part of the upper column, that is, the more the theoretical plate numberis, the higher the oxygen purityis;

 

3.The relationship between oxygen extraction rate and oxygen purity: the oxygen purity is inversely proportional to the oxygen extraction rate;

 

4.The relationship between upper columnpressure and oxygen purity: the oxygen purity is inversely proportional to the upper columnpressure, that is, the higher the upper column pressure, the lower the oxygen purity;

 

5.The relationship between the extraction amount of middle pressure nitrogen in the lower columnand the purity of oxygen: the purity of oxygen is inversely proportional to the amount of nitrogen extracted from the lower column, that is, the purity of oxygen decreases with the increase of the amount of nitrogen extracted from the lower column.

DEAR Air Separation Solve YourFactors affecting oxygen purity in air separation plantYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top