当前位置: Home / Faq / Air separation parts FAQ /

There are several starting methods for asynchronous motor. What problems should be noted?

There are several starting methods for asynchronous motor. What problems should be noted?
Nov 28, 2024
Author: DEAR AST
Question Reply

Air separation equipmentWhen the general motor is started, the current that the stator of the motor takes from the power grid is about 5 ~ of the rated current of the motor ~ 7 times. After starting the small motor for one or two seconds, the current decreases rapidly as the rotating speed of the rotor gradually rises; while the large motor needs more than ten seconds, even dozens of seconds before the rotor reaches the stable rotating speed. That is, until the start-up ends, the current drops to the rated value.
If the starting current of asynchronous motor is high, what problems will it bring to the use? If this motor starts frequently when it is used, the motor will heat severely due to the influence of starting current, which will affect the normal service life of the motor. In addition, if the starting times of the motor used are not frequent, when its capacity exceeds 30% of the power transformer capacity, due to the large starting current, it will cause the overvoltage drop on the power transmission line of the transformer, which will affect the work of other electrical equipments connected to the same transformer. Therefore, certain measures must be taken when starting to limit the starting current from being too large. Due to different types of motors used and different production conditions, the starting methods of motors are also different.
As for squirrel cage motor, as long as the power grid permits and the starting times are not very frequent, direct starting should be adopted as far as possible. After the constant dry winding is connected, it is directly connected to the rated voltage. Using direct start is the simplest and most economical, and there is no need to start the equipment. If the capacity of squirrel cage motor is relatively large, in order to limit its starting current, it generally adopts step-down starting. Step-down start is to add a lower voltage rather than a rated voltage to the motor when the motor starts. This can greatly reduce the starting current. The commonly used decompression method is Y-△ start. This method can be applied to motors with low starting load such as fans and water pumps. There are many methods to start the step-down, but the squirrel cage motor uses Y-△ to start. The equipment used is simple, small in size, light in weight, easy to maintain and low in price, so it is most commonly used.
Winding motor often has heavy load when starting, in order to limit the starting current, the stator is connected with rated voltage, and the rotor circuit is connected with resistance or frequency sensitive rheostat. This method can not only reduce the starting current, but also increase the starting torque.

DEAR Air Separation Solve YourThere are several starting methods for asynchronous motor. What problems should be noted?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Liquid air separation plant solutions Most liquid air separation plant cold energy receiving stations have a peaking role, their use is generally for domestic gas or car refuelling, with high and intermittent periods of gas consumption, for example 1-2 hour peaks in the morning and midnight. If the liquid air separation plant vapourisation plant is intermittent, the plant will not operate continuously. The solution is based on the intermittent use of liquid air separation plant and is character...
2026.07.08
In the main column of the air separation column, the distribution of argon varies with the position of the liquid air inlet. With the increase of liquid air inlet position, the maximum concentration of argon enrichment zone in the stripping section also increases, and the nitrogen content in the distillate can be reduced. However, the argon content in the downstream also increases. In order to ensure the purity of oxygen, more trays are needed under the extraction port of argon fraction. Therefore, in the case of producing argon, the position of liquid air supply E1 should be appropriately increased compared with the case of not producing argon. Some unit is equipped with two liquid air inlet positions to meet the conditions of argon production and non argon production respectively. In the production of argon, in order to improve the extraction rate of argon, the content of argon in oxygen and nitrogen must be reduced. When the content of argon in exhaust nitrogen is more than 0.3%
2026.07.07
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top