Oct 23, 2023
Author: DEAR AST
Question Reply

Pressure dew point: after the wet air is compressed, the density of water vapor increases and the temperature also rises. When the compressed air cools down, the relative humidity will increase. When the temperature continues to drop to 100%, water drops will come out from the compressed air, the temperature at this time is the "pressure dew point" of compressed air ".

The relationship between pressure dew point and normal pressure dew point

The corresponding relationship between the pressure dew point and the normal pressure dew point is related to the "compression ratio", which is generally expressed by charts. Under the condition of the same "pressure dew point", the higher the "compression ratio" is, the lower the normal pressure dew point it corresponds to IS. For example: when the compressed air pressure dew point of O.7MPa is 2℃, the normal pressure dew point is-23℃. When the pressure increases to 1.0MPa and the dew point of the same pressure is 2℃, the corresponding normal pressure dew point drops to-28℃

Pressure dew point measurement

Although the unit of pressure dew point is ℃, its connotation is the water content of compressed air. Therefore, measuring the dew point is actually measuring the moisture content of the air. There are many instruments for measuring compressed air dew point, such as mirror dew point meter, electric sensor Dew Point meter, dielectric method Dew Point meter, Crystal oscillating Dew Point meter, infrared Dew Point meter, semiconductor sensor Dew Point meter, such as MICHELL Dew Point meter in Britain, the measuring range of this instrument can reach-100℃.

Precautions for measuring pressure dew point 

Use the dew point meter to measure the air dew point, especially when the water content of the tested air is very low, the operation should be very careful and patient. Gas SamplingAir separation equipmentAnd connection pipeline must be dry (at least more dry than the measured gas), pipeline connection should be completely sealed, gas flow rate should be selected according to the provisions, moreover, a long enough pretreatment time is required. A little carelessness will lead to a large error. It is proved that there is a big error when measuring the "pressure dew point" of the compressed air processed by the cold dryer by using the "micro-moisture analyzer" using phosphorus pentoxide as electrolyte. According to the manufacturer's explanation, this is because the compressed air will produce "secondary electrolysis" during the test process, which makes the read value higher than the actual value.

DEAR Air Separation Solve YourKnowledge about stress dew pointYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top