Pure argon Tower and the condensation evaporator composite should be met:

1.Pure argon TowerAnd condensing evaporator is manufactured, inspected and checked and accepted according to the relevant provisions of JB/T2549-1994 "aluminum air separation equipment manufacturing technical specification" and JB/T4734-2002 "Aluminum Welding container.

2. the welding joints of Class A and B of containers should be 100% x-ray tested to meet the n-level requirements of JB/T4730-2005 nondestructive testing of pressure-bearing equipment; the welding joints of class C and D should be 100% permeated tested, if the quality reaches Grade I of JB/T4730-2005, it is qualified.

3. after the compounding, Channel I (the outside of the upper part) first conducts the strength test with 0.23MPa gas, then decreases to 0.15MPa gas tightness test; Channel II (pure hydrogen Tower) conducts the strength pressure test with 0.104MPa gas, then lower the pressure to 0.08MPa to conduct air-tightness test; III channel to conduct strength test with 0.69MPa gas, then lower to 0.55MPa to conduct air-tightness test; test medium is dry and clean air or nitrogen, test procedures and requirements should be conducted according to pressure vessel safety technology supervision regulations.

4. All parts must be passivated with oil before assembling.

5. After compounding and pressure test, blow the inner and outer surfaces to remove dirt.

DEAR Air Separation Solve YourWhat technical requirements should be met when the pure argon tower is compounded with the condensing evaporator?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Screw compressor is a positive displacement compressor from the mechanical type, which is composed of the driving rotor and driven rotor, the main body and a pair of synchronous gears. Therefore, the common faults of screw compressor are as follows: 1. The bearing is burnt out. Because of the foreign matter in the oil system, the oil pressure and the quality of the oil are reduced, resulting in the bearing burning out. The main treatment methods are: check the oil supply system; clean the oil filter and the cooling pipe of the oil cooler; check and adjust the oil pressure regulating valve; test the oil quality, and replace the oil when it is not good; check and deal with the oil leakage points. 2. The rotor is burnt out. When foreign matters enter into the compressed medium system, the temperature of the rotor rises, the temperature of the cooling oil of the rotor increases due to the high temperature of the inhaled medium, and the compression ratio increases, which may cause the
2026.03.20
Why only cryogenic air separation equipment can be selected for large industrial gas?
2026.03.19
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top