How does water precipitate in the cooler (or switching heat exchanger?

How does water precipitate in the cooler (or switching heat exchanger?
Sep 27, 2023
Author: DEAR AST
Question Reply

When air enters into the cooler (or switching heat exchanger) through the last stage cooler of air compressor and nitrogen water precooler, the content of water vapor in the air has reached the saturated state. After that, with the decrease of temperature, the corresponding pressure of saturated water vapor is decreasing; the content of saturated water per cubic meter of air is gradually decreasing. For example, when the temperature drops from 30℃ to-60℃, the saturated moisture content in the air changes from 30.3 g/m3Reduce to 0.011 g/m3. The extra water is precipitated in the stuffing or plate-wing type of the cooler.Heat exchangerOn the fin. At-60℃, the saturated water vapor pressure has decreased to 1.067 Pa, which can be considered as no water, so 30℃ to-60℃ is called the water precipitation area.
The "three-phase point" of water (the state of the coexistence of gas phase, liquid phase and solid phase) pressure is 0.613kPa, and the temperature is 0.01 ℃. When the partial pressure of the water vapor in the air is higher than that of the three-phase point, the air temperature reaches the saturation temperature and the water vapor is precipitated in the liquid state. Changing from gas phase to liquid phase is called "condensation" or "liquefaction ". When the partial pressure of water vapor in the air is lower than that of the three-phase point, and the air temperature reaches the saturation temperature, the water vapor is directly precipitated in the solid state, and it is called "crystallization" or "Solidification" from the gas phase to the solid phase without going through the liquid state ". The air temperature drops from 30℃ to 0℃, and the partial pressure (saturated vapor pressure) of water vapor is always higher than that of three-phase point, so the eluate in this temperature range is water drops or water membrane. When the temperature is reduced from 0℃ to-60℃, the saturated vapor pressure is lower than the pressure of three-phase point, and the precipitate of vapor is frost or snowflake-like (when the moisture content is too large, it will freeze into ice ).

DEAR Air Separation Solve YourHow does water precipitate in the cooler (or switching heat exchanger?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top