What conditions limit the inflated air volume entering the tower?

What conditions limit the inflated air volume entering the tower?
Apr 22, 2024
Author: DEAR AST
Question Reply

The expansion air volume entering the upper tower increases, and the reflux ratio of the distillation section decreases correspondingly. In order to achieve the required purity of nitrogen products, more tower plates need to be set. When the reflux ratio is reduced to countless Tower plates needed to be set to make the purity of nitrogen reach the required value, then the reflux ratio is called the minimum reflux ratio. The expansion air volume entering the upper tower is first limited by the minimum reflux ratio. The closer the reflux ratio is to the minimum reflux ratio, the faster the number of tower plates needed to ensure the product purity increases, which will lead to the increase of investment, the increase of tower plate resistance, the increase of Operation pressure and the increase of energy consumption. Therefore, the reflux ratio after the inflated air enters the tower should be larger than the minimum reflux ratio.


When the purity of nitrogen is required to be low, the minimum reflux ratio will also decrease, and the expansion air volume allowed to enter the upper tower will be more, then the extraction rate of oxygen will accordingly decrease. In addition, if the purity of liquid space is high, the amount of liquid space will be less, and the corresponding amount of liquid nitrogen will increase. This will increase the reflux ratio of the distillation section and allow the expansion air volume to be sent into the upper tower to increase appropriately. The purity of oxygen is lower, and the amount of inflated air that is allowed to be delivered can be larger. In a word, the inflated air volume sent to the upper tower should comprehensively consider the influence of factors such as reflux ratio, Tower plate number, oxygen, nitrogen and liquid-air purity, so as to ensure the product purity and not to reduce the oxygen extraction rate too much, under the condition of not increasing the number of tower plates and energy consumption too much, send proper amount of air expansion. At present, generally, the expansion air volume allowed to be sent to the upper tower is 0.15 ~ 0.25 processing air volume. For large scaleAir separation equipment, The cold loss is small. The inflated air needed to make up for the cold loss will not exceed the above requirements, so all the inflated air can be sent to the upper tower. For small and medium-sizedAir separation equipment, The cold damage is relatively large. If the expansion volume is greater than the above requirements, if all the expansion air is sent to the upper tower, the number of tower plates will increase too much, and the energy consumption will also increase significantly at the same time. When designing, we would rather only send part of the air to the upper tower, and the other part of the air will pass through to the heat exchanger and only recover its cooling capacity, which is more economical and reasonable.

DEAR Air Separation Solve YourWhat conditions limit the inflated air volume entering the tower?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Water evaporation, wind-blown losses and other situations occurring in industrial circulating cooling water system operation, resulting in the continuous concentration of circulating water, then the salts contained therein exceed the standard, anions and cations increase, PH value changes significantly, resulting in the deterioration of water quality. The temperature of the circulating water rises and the PH value and nutrients increase, which is conducive to the reproduction of microorganisms. ...
2026.06.03
If the temperature after the expander of the air separation unit is too low, it should find out the cause of the low temperature and take measures to increase the temperature after the expander. If the low temperature of expander is caused by liquid air in front of expander, appropriate measures should be taken to reduce the liquid air level of lower column. If it is caused by other reasons, the more effective method is generally throttling in front of the expander. Throttling will not increase the temperature in front of the expander, but throttling will reduce the pressure in front of the expander, so the pressure difference between the front and the back of the expander will be reduced, the expander will do less work and the temperature will be reduced, so the temperature at the after of the expander can be increased.
2026.06.01
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top