Question Reply

The expansion air volume entering the upper tower increases, and the reflux ratio of the distillation section decreases correspondingly. In order to achieve the required purity of nitrogen products, more tower plates need to be set. When the reflux ratio is reduced to countless Tower plates needed to be set to make the purity of nitrogen reach the required value, then the reflux ratio is called the minimum reflux ratio. The expansion air volume entering the upper tower is first limited by the minimum reflux ratio. The closer the reflux ratio is to the minimum reflux ratio, the faster the number of tower plates needed to ensure the product purity increases, which will lead to the increase of investment, the increase of tower plate resistance, the increase of Operation pressure and the increase of energy consumption. Therefore, the reflux ratio after the inflated air enters the tower should be larger than the minimum reflux ratio.


When the purity of nitrogen is required to be low, the minimum reflux ratio will also decrease, and the expansion air volume allowed to enter the upper tower will be more, then the extraction rate of oxygen will accordingly decrease. In addition, if the purity of liquid space is high, the amount of liquid space will be less, and the corresponding amount of liquid nitrogen will increase. This will increase the reflux ratio of the distillation section and allow the expansion air volume to be sent into the upper tower to increase appropriately. The purity of oxygen is lower, and the amount of inflated air that is allowed to be delivered can be larger. In a word, the inflated air volume sent to the upper tower should comprehensively consider the influence of factors such as reflux ratio, Tower plate number, oxygen, nitrogen and liquid-air purity, so as to ensure the product purity and not to reduce the oxygen extraction rate too much, under the condition of not increasing the number of tower plates and energy consumption too much, send proper amount of air expansion. At present, generally, the expansion air volume allowed to be sent to the upper tower is 0.15 ~ 0.25 processing air volume. For large scaleAir separation equipment, The cold loss is small. The inflated air needed to make up for the cold loss will not exceed the above requirements, so all the inflated air can be sent to the upper tower. For small and medium-sizedAir separation equipment, The cold damage is relatively large. If the expansion volume is greater than the above requirements, if all the expansion air is sent to the upper tower, the number of tower plates will increase too much, and the energy consumption will also increase significantly at the same time. When designing, we would rather only send part of the air to the upper tower, and the other part of the air will pass through to the heat exchanger and only recover its cooling capacity, which is more economical and reasonable.

DEAR Air Separation Solve YourWhat conditions limit the inflated air volume entering the tower?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What's the reason for using two-stage distillation column in air separation column?Usually, the air in the lower column is pre separated by the air separation column, which is rectified into liquid air which is rich in oxygen and pure nitrogen, and then further rectified in the upper column to obtain oxygen and nitrogen products. The connection between the upper and lower columns is the condensing evaporator. It uses the pressured nitrogen of the lower column to heat the liquid oxygen in the upper column, so as to evaporate the liquid oxygen while condensing the liquid nitrogen. The advantage of using two-stage distillation column is that the product has high extraction rate, and high purity oxygen and nitrogen can be obtained at the same time. Oxygen and nitrogen products can also be produced in a single-stage distillation column, but only one product can be produced separately. It is similar to the lower column of two-stage distillation column, in which pure nitrogen product can be
2026.11.17
Answer: to judge whether the air separation unit is advanced or not, it mainly depends on three hard indicators, combined with the comprehensive evaluation of the intelligent level. 1. Core evaluation index -Unit power consumption: commonly measured in kwh/nm ³ o ɑ, it is the operating cost index that customers are most concerned about; The larger the scale and the higher the purity, the lower the unit energy consumption. -Oxygen extraction rate: it reflects the utilization efficiency of raw air. The higher the extraction rate, the more electricity is saved. The cryogenic method is usually better than the simple process. -Operation stability and load regulation range: whether the load can be changed smoothly between 30% and 110% will directly affect the ability of adaptive gas fluctuation. 2. Embodiment of the advanced nature of Deere air separation -The eighth generation of intelligent air separation technology: make system optimization in process organization and equipment matching,
2026.11.16
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top