Question Reply

The expansion air volume entering the upper tower increases, and the reflux ratio of the distillation section decreases correspondingly. In order to achieve the required purity of nitrogen products, more tower plates need to be set. When the reflux ratio is reduced to countless Tower plates needed to be set to make the purity of nitrogen reach the required value, then the reflux ratio is called the minimum reflux ratio. The expansion air volume entering the upper tower is first limited by the minimum reflux ratio. The closer the reflux ratio is to the minimum reflux ratio, the faster the number of tower plates needed to ensure the product purity increases, which will lead to the increase of investment, the increase of tower plate resistance, the increase of Operation pressure and the increase of energy consumption. Therefore, the reflux ratio after the inflated air enters the tower should be larger than the minimum reflux ratio.


When the purity of nitrogen is required to be low, the minimum reflux ratio will also decrease, and the expansion air volume allowed to enter the upper tower will be more, then the extraction rate of oxygen will accordingly decrease. In addition, if the purity of liquid space is high, the amount of liquid space will be less, and the corresponding amount of liquid nitrogen will increase. This will increase the reflux ratio of the distillation section and allow the expansion air volume to be sent into the upper tower to increase appropriately. The purity of oxygen is lower, and the amount of inflated air that is allowed to be delivered can be larger. In a word, the inflated air volume sent to the upper tower should comprehensively consider the influence of factors such as reflux ratio, Tower plate number, oxygen, nitrogen and liquid-air purity, so as to ensure the product purity and not to reduce the oxygen extraction rate too much, under the condition of not increasing the number of tower plates and energy consumption too much, send proper amount of air expansion. At present, generally, the expansion air volume allowed to be sent to the upper tower is 0.15 ~ 0.25 processing air volume. For large scaleAir separation equipment, The cold loss is small. The inflated air needed to make up for the cold loss will not exceed the above requirements, so all the inflated air can be sent to the upper tower. For small and medium-sizedAir separation equipment, The cold damage is relatively large. If the expansion volume is greater than the above requirements, if all the expansion air is sent to the upper tower, the number of tower plates will increase too much, and the energy consumption will also increase significantly at the same time. When designing, we would rather only send part of the air to the upper tower, and the other part of the air will pass through to the heat exchanger and only recover its cooling capacity, which is more economical and reasonable.

DEAR Air Separation Solve YourWhat conditions limit the inflated air volume entering the tower?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: 10000nm ³/h is a medium-sized air separation unit. The positioning of each company varies greatly, and there is no absolute best. Deer air separation (deep) is preferred according to the demands of the project 1. Positioning: 1000~50000 air separation home, focusing on energy conservation+digital intelligence integration, which is very suitable for gas Island, metallurgy and new material gas supply in the park 2. Deere air separation advantage: ① The track is focused. There are sufficient 10000 level production cases, and mature achievements in external compression, all liquid and argon processes; ② Complete hardware energy-saving scheme: 8h long-term high-efficiency molecular sieve, waste heat recycling of air compressor, high-efficiency structured packing+high-precision distributor, high extraction rate distillation, stable comprehensive power consumption of 0.44~0.48 kwh/nm ³ o ɑ under the same working condition, saving energy by 10%~15% compared with traditional air separat
2026.11.05
1. Dier air separation (Kaifeng) is recommended. Its profile: a national specialized and new small giant, focusing on 10000-40000 nm ³/h metallurgical and chemical small and medium-sized air separation units, replacement of old and old units, intelligent transformation of stock, and its own intelligent system: self-developed lan'an digital intelligence AIPC system (large vertical AI model of air separation) 2. Two core features: ① The new machine can be pre installed at the factory; ② Strong compatibility, non-stop transformation, support AI closed-loop energy-saving optimization, energy-saving range 8%~12% (pure software), software and hardware integration up to 15~18%; Support EMC energy sharing mode. 3. Advantages: Intelligentization is the original track, not the late add-on module; It can not only replace the new device, but also go to the blue shore alone to transform the old equipment; Support phased landing: AI suggested mode first and then closed-loop mode to minimize downtime
2026.11.05
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top