Plate and fin heat exchangers in actual operation will have a certain degree of fouling, corrosion and blockage problems, resulting in uneven distribution of logistics, due to the harsh operating environment, the heat exchanger will usually have a certain degree of tilt, received inertial forces and gravity double impact, the uneven distribution of logistics is significantly more serious than the horizontal state.
Cases of Mechanical causes of small air separation unit fin heat exchangers
More
News of Mechanical causes of small air separation unit fin heat exchangers
More
Aug 11, 2025
DEAR Air Separation Fulfills Client Commitments Through Action
Apr 08, 2025
DEAR Air Separation Successfully Tops Out 40,000 Nm³/h Rare Gas Extraction Intelligent Air Separation Equipment Project
Albums of Mechanical causes of small air separation unit fin heat exchangers
More
Solutions of Mechanical causes of small air separation unit fin heat exchangers
More
1500/100 Y-type solution for small air separation plant in new material industry
The new material industry system of our country has been initially formed and the development situation is good. With the introduction of national strategic planning such as "The development plan of national strategic emerging industries in the 13th Five-Year Plan" and "The development plan of new material industry in the 13th Five-Year PlanThe new material industry system of DEAR air separation has been initially formed and the development situation is good. With the introduction of national strategic planning such as "The development plan of national strategic emerging industries in the 13th Five-Years Plan" and "The development plan of new material industry in the 13th Five-Years Plan", it has created a good policy environment for the development of new material industry. Recently, DEAR air separation cooperated with clients on the 1500/100 Y-type project of small air separation plant. The overall design of the project is reasonable, and the one-time drive is successful, and all the
4500/4500-type solution for small and medium-sized air separation plant in nonferrous industry
According to the influence and reform of the general environment of the non-ferrous industry, the problems faced by this industry are becoming more and more serious, and the control of production capacity is particularly important. Recently, the 4500/4500 type small air separation equipment project signed with customers by DEAR Air Separation, through the trial run stage, all the technical indicators have reached or exceeded the design standard, and have been continuously sending nitrogen for several days, which has been well received by users.
Faq of Mechanical causes of small air separation unit fin heat exchangers
More
What are the key technical components of an air separation unit?
Aug 12, 2025
Due to improper adjustment of seal gas pressure during operation, liquid oxygen pump can not pump liquid or leak.   From the quality point of view, when the sealing pressure is too high, there will be gas leakage into the pump through the labyrinth seal, resulting in the impeller with gas or even idling, resulting in liquid injection or pressure drop; when the air pressure before sealing is too low, there will be liquid oxygen leakage.   From the quantity point of view, when (p1-p3...