This device recycles and reuses argon gas. Using this series of devices is a powerful measure to reduce production costs, save energy, and improve economic benefits. From the perspective of improving the low-carbon environment, argon recovery is also a significant work in the future development.
The argon purification and recovery device is the argon gas (recovery pressure slightly higher than atmospheric pressure) containing various impurities that was directly discharged into the atmosphere through the primary filtration dust and backflush recovery device, precision secondary filtration, pressurized by the compressor, and frozen dryer dehydration, deoxidizer, oxygen, deep adsorption of the drying equipment to remove trace oxygen, water and gas impurities in the argon, fully automatic argon recovery and purification system, high purity argon recovery and purification equipment to obtain extremely high purity argon , and finally sent to the working point through the precious metal precision filter.
KDAr-1500 Product advantages |
The device adopts molecular sieve purification, back-filled liquid argon to supplement the cooling capacity, and at the same time, a deep-cooled full distillation argon purification process. This process is safe and reliable, and it is also economically reasonable. The main reasons are: 1. Good security The entire device has low operating pressure, simple technology, high equipment safety, long switching cycle of the molecular sieve system, increased service life of the switching valve, and reduced hidden safety hazards. 2. High reliability. 3. Easy operation and maintenance, simple process. |
Technical Parameters | |||||
Products |
Output N m³/h |
Purity |
Outlet cold box pressure Mpa |
Temperature |
Note |
Argon |
1800 |
≤1.5ppmO2 ≤0.5ppmH2 |
0.55 |
Normal temperature |
Send out directly |
Note: The measurement unit Nm3 / h is measured at 0 ℃ and 0.1013Mpa (A). It is called standard quantity.
1.1 Argon extraction rate: ≥85%
Argon flow: ≥1600Nm³ / h (when the raw material is 2000Nm³ / h)
Argon outlet pressure: ≥0.55MPaG
Argon purity: H2≤0.5ppm
O2≤1.5ppm
N2≤4
Other impurities, meeting the requirements of GB / T4842-2006 for high purity argon (99.999%)
Cooling method: liquid argon backfilling, argon volume of backfilling liquid ≤200Nm³ / h
1.2 Operating cycle (two large heating intervals): ≥ 2 years
1.3 Device heating and cooling time: ~ 36 hours
1.4 Device startup time (from the start of the expander until the oxygen product reaches the purity index): ~ 40 hours
Supporting unit | Unit |
1. Oil-free screw type argon compressor | 1 Set |
2. Air precooling system | 1 Set |
3. Hydrogen deaeration system | 1 Set |
4. Drying and purification system | 1 Set |
5. Fractionation tower system | 1 Set |
6. Liquid argon storage backfill system (including backup system vaporizer) | 1 Set |
7. Instrument control system | 1 Set |
8. Electronic control system | 1 Set |