Installation of air separation unit

Installation of air separation unit
The installation of air separation unit is generally divided into machine installation, unit installation, valve and pipeline installation, electric control system installation, instrument control system installation and auxiliary system installation according to the process and function. After the installation of the air separation unit is completed and passed the inspection, the single unit test run and linkage test run can be carried out.
News of Installation of air separation unit
More
Sep 30, 2020
On September 24, a delegation from QinZhou Federation of Industry and Commerce of Guangxi province came to DEAR air separation for investigation and i
Sep 11, 2020
On September 7, it was reported that in order to prevent and control environmental pollution by solid waste, protect public health, maintain ecologica
Topic of Installation of air separation unit
More
Solutions of Installation of air separation unit
More
Small air separation plant KDON-10000/10000 solution for metallurgical industry
The metallurgical industry has its unique industry characteristics and high requirements for oxygen purity. DEAR air separation has cooperated with domestic and foreign metallurgical industry customers in many projects, has rich project experience, and has continuously invested funds to develop energy-saving and intelligent air separation plant. KDON-10000/10000 is highly praised by customers for its high efficiency and stable operation.
Large air separation plant KDON-20000/20000 solution for metallurgical industry
DEAR air separation has cooperated with customers in metallurgical industry domestic and abroad in many projects, and has rich project experience. DEAR has continuously invested in the research and development of large-scale air separation plant. In view of metallurgical industry, DEAR combined with the characteristic of this industry, develops high-efficiency energy-saving air separation plant, to meet the needs of large and medium customers. DEAR air separation uses the rapid development of internet technology to establish a remote monitoring system to collect real-time operation data of each air separation plant, and provides the best suggestions for users by using big data analysis.
Faq of Installation of air separation unit
More
The temperature condition adjustment of the cooler (or switching heat exchanger) is based on the central temperature. The "middle" mentioned here does not refer to the central position of geometric dimension, but refers to the temperature on the barrel (or switching channel) near the central air extraction or the outlet of circulation. It is also related to the location where the thermometer is installed. The purpose of temperature condition adjustment is to keep the temperature difference between cold end and hot end within the specified range. Then, why should the temperature in the middle prevail? We need to take a look at the relationship between the temperature of the middle part and the temperature difference of the cold end and the temperature difference of the hot end, and what rules the temperature changes along the height direction of the cooler (or the switching heat exchanger) follow. The temperature condition change of the cooler (or switching heat exchanger) is general...
Apr 23, 2025
The start-up phase of the whole low-pressure oxygen generator is that liquid empty appears first in the lower tower, and then liquid oxygen appears in the upper tower. The cold energy needed to accumulate liquid in the tower mainly comes from the expansion machine, which uses the low temperature gas after expansion to make part of the air liquefaction in the liquid purifier. But the upper tower itself can not produce liquid, it mainly depends on the liquid from the lower tower into the upper tower. In the phase of hydrops, in order to accumulate the liquid level as soon as possible, the cooling volume should be transferred to the tower as much as possible, the phenomena of overcooling, temperature difference at the hot end and cold loss increase caused by excess cooling of switching heat exchanger should be avoided. As for how to recycle and transfer the cold volume of the air expansion into the tower, whether it is by the liquid purifier to transfer the cold volume to the lower tow...
Apr 15, 2025
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top