The metallurgical industry has its unique industry characteristics and high requirements for oxygen purity. DEAR air separation has cooperated with domestic and foreign metallurgical industry customers in many projects, has rich project experience, and has continuously invested funds to develop energy-saving and intelligent air separation plant. KDON-10000/10000 is highly praised by customers for its high efficiency and stable operation.
Solution advantages |
The unit adopts molecular sieve purification, booster turbine expander to supply the cooling capacity of the unit. This process is safe, reliable and economical. The main reasons are as follows:
1.Good safety The whole set of device has the advantages of low operating pressure, simple process, high equipment safety, long switching cycle of molecular sieve system, increased service life of switching valve, and reduced potential hazards. A large amount of liquid oxygen is extracted from the main cooling (K1) to minimize the possibility of hydrocarbon accumulation.
2.High reliability A large amount of surplus nitrogen can be sent to the water cooling tower, reducing the load of the water chiller, reducing the energy consumption and cost of air separation, so that the reliability of the device is further improved.
3.Convenient operation and maintenanceandsimple process |
PRODUCT |
OUTPUT N m³/h |
PURITY |
PRESSURE OUT OF COLD BOX Mpa |
TEMP |
NOTE |
OXYGEN |
10000 |
≥99.6% O2 |
0.015 |
NORMAL |
EXTERNAL COMPRESS TO 2.5Mpa |
LOX |
500 |
≥99.6% O2 |
Into tank |
SATURATED |
|
Nitrogen |
10000 |
≤100ppmO2 |
0.008 |
NORMAL |
To pre-cooling system |
Nitrogen |
10000 |
≤100ppmO2 |
0.008 |
NORMAL |
EXTERNAL COMPRESS TO 2.5Mpa |
Note: the unit of measurement Nm3/h is measured at 0 ℃, 0.1013Mpa (A). It is called standard state quantity.
1.1 Take oxygen and nitrogen at different times
1.2 Operation cycle (interval between two large heating): ≥ two years
1.3 Heating and uncooling time of the device: ~ 36 hours
1.4 Starting time of the device (from the start of expander to the purity of oxygen product): ~ 40 hours
Matching Units |
Unit |
1. Centrifugal air compressor 2. Air pre-cooling system 3. Purification system 4. Booster turbine expander 5.Fractionator system 6.Oxygen compression system 7. Nitrogen compression system 8.Liquid storage system 9.Instrument control system 10.Electric control system |
1 Set 1 Set 1 Set 1 Set 1 Set 1 Set 1 Set 1 Set 1 Set 1 Set |