DEAR air separation won the trust of Meihua Group with advanced technical scheme, high quality standard and thoughtful service system, and finally won the bid through multiple bids, and signed the KDON (AR) - 13000 / 22000 / 350 air separation equipment contract. In April 2020, a successful start-up, the production and purity are up to the user requirements. After 72 hours of operation, all indexes are better than the design standard, the equipment is stable so far.
The unit adopts molecular sieve purification, booster turbine expander to supply the cooling capacity of the unit, and the whole rectification hydrogen-free argon production process, which is safe, reliable and economical. The main reasons are as follows:
1.Good safety
The whole set of device has the advantages of low operating pressure, simple process, high equipment safety, long switching cycle of molecular sieve system, increased service life of switching valve, and reduced potential hazards.
A large amount of liquid oxygen is extracted from the main cooling (K1) to minimize the possibility of hydrocarbon accumulation.
2.High reliability
A large amount of surplus nitrogen can be sent to the water cooling tower, reducing the load of the water chiller, reducing the energy consumption and cost of air separation, so that the reliability of the device is further improved.
3.Convenient operation and maintenanceandsimple process
PRODUCT |
OUTPUT N m³/h |
PURITY |
PRESSURE OUT OF COLD BOX Mpa |
TEMP |
NOTE |
OXYGEN |
13000 |
≥99.6% O2 |
0.015 |
NORMAL |
EXTERNAL COMPRESS TO 2.1Mpa |
LOX |
300 |
≥99.6% O2 |
Into tank |
SATURATED |
|
Nitrogen |
10000 |
≤10ppmO2 |
0.008 |
NORMAL |
To pre-cooling system |
Nitrogen |
12000 |
≤10ppmO2 |
0.008 |
NORMAL |
EXTERNAL COMPRESS TO 1.0Mpa |
LAr |
350 |
≤1.5ppmO2 |
Into tank |
SATURATED |
|
Note: the unit of measurement Nm3/h is measured at 0 ℃, 0.1013Mpa (A). It is called standard state quantity.
1.1 Take oxygen and nitrogen at different times
1.2 Operation cycle (interval between two large heating): ≥ two years
1.3 Heating and uncooling time of the device: ~ 36 hours
1.4 Starting time of the device (from the start of expander to the purity of oxygen product): ~ 40 hours
Matching Units |
Unit |
1. Centrifugal air compressor 2. Air pre-cooling system 3. Purification system 4. Booster turbine expander 5. Fractionator system 6.Nitrogen compression system 7.Oxygen compression system 8.Liquid storage system 9.I & C system 10.Electric control system |
1 set 1 set 1 set 1 set 1 set 1 set 1 set 1 set 1 set 1 set |