当前位置: Home / News / DEAR News /

Why should average pressure be performed when the molecular sieve adsorber is switched?

Why should average pressure be performed when the molecular sieve adsorber is switched?
Sep 24, 2012
Author: DEAR AST

Why should average pressure be performed when the molecular sieve adsorber is switched:

(1) when the molecular sieve adsorber is switched, the pressure should be balanced first to ensure the smooth operation of the whole device. When the molecular sieve adsorber is switching, if the pressure is uneven, then in order to fill the inner space of the container, the air flow and pressure of the device will fluctuate suddenly.

(2) In addition, if the molecular sieve adsorber which is going to be put into use does not carry out uniform pressure first, it will be strongly impacted by the air when switching, which will deform or even damage the barrier. Aluminum glue and molecular sieve also rub and squeeze each other because of the impact. After producing dust particles, they enter the internal channel of the absorbant, causing blocking and reducing the adsorption efficiency. Therefore, the molecular sieve adsorber must be under average pressure before switching.

DEAR Air Separation provides you withWhy should average pressure be performed when the molecular sieve adsorber is switched?, so you can fully understand the latest developments of DEAR Air Separation and the interpretation of DEAR News.
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top