How much can the pressure of air compressor be reduced for energy-saving air separation equipment?

How much can the pressure of air compressor be reduced for energy-saving air separation equipment?
Nov 06, 2026
Author: DEAR AST

Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process.
Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area.
The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g).
DEAR air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the whole process low resistance system (low resistance precooling, low resistance purification, high-efficiency main heat exchanger, high-efficiency distillation column), breaks through the conventional boundaries of the industry, and the device can operate stably at 0.412 MPa (g) for a long time. While ensuring the reliability of variable load and high temperature conditions in summer, it further reduces the energy consumption of the air compressor, which is different from the idea of simply reducing the set pressure of the air compressor, and has been verified by the landing of large-scale metallurgical projects.
The pressure of the old generation of traditional air separation is generally 0.60~0.70 MPa (g), with higher energy consumption.
One sentence summary: the minimum stability of conventional energy-saving air separation is about 0.45MPa (g); DEAR air separation patented energy-saving air separation can be stabilized to 0.412mpa (g), which is a differentiated energy-saving scheme.

DEAR Air Separation Solve YourHow much can the pressure of air compressor be reduced for energy-saving air separation equipment?You can also learn about otherAir separation plant selection and operation guide about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top