During the operation of the air separation plant, the expanded air sent to the upper tower must be strictly maintained in a slightly overheated state, which is the core operating standard for taking into account the operation safety of the expander and the stability of the upper tower distillation condition. The industry has formulated a unified micro superheat control range for the full low-pressure external compression air separation unit. The conventional controllable range is 3 ℃ -8 ℃, and the optimal control range for the stable operation of the unit is 4 ℃ -6 ℃.
Micro superheat temperature has clear working condition boundary requirements. When the superheat is lower than 3 ℃, the air working condition approaches to the saturated state. Affected by the pressure fluctuation of the device, the cold loss of the pipeline and other factors, it is very easy to precipitate liquid droplets. The high-speed air flow with liquid will impact the impeller of the expander, causing wear and vibration of the equipment, causing liquid hammer failure, which seriously threatens the operation safety of the equipment. When the superheat degree is higher than 8 ℃, excessive air superheat will bring a large amount of excess heat to the upper tower, increase the consumption of cooling capacity in the tower, reduce the reflux ratio in the distillation section, resulting in the decline of gas-liquid mass transfer efficiency, and ultimately cause the fluctuation of oxygen and nitrogen product purity, the reduction of oxygen extraction rate, and the increase of energy consumption of the device.
It is important to clarify that the superheat is the temperature difference, not the fixed temperature value, which is calculated from the actual temperature at the expander outlet and the air saturation temperature under the corresponding pressure. During the start-up and cooling stage of the unit, it can be temporarily relaxed to 5 ℃~ 10 ℃. Under normal and stable conditions, the optimal range should be strictly locked. At the same time, the DCS should be used to calculate the difference in real time to avoid the measurement error caused by pressure fluctuation and ensure the safe, efficient and economic operation of the unit.

DEAR Air Separation Solve YourAir separation expansion air micro superheat temperature control standard and practice specification?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top