What precautions shall be taken for the regulation of excess oxygen in the air separation unit?

What precautions shall be taken for the regulation of excess oxygen in the air separation unit?
Apr 23, 2026
Author: DEAR AST

In the air separation unit, when the oxygen enrichment needs to reduce the output, the core regulation principle is: first stabilize the working condition, then reduce the output, anti-nitrogen plug, maintain the purity, control the pressure difference, and operate stably and orderly to avoid working condition disorder. The specific precautions are as follows:
First, reduce the air volume and then the oxygen output. It is forbidden to close only the oxygen outlet without reducing the air volume into the column. Gradually reduce the load of the air compressor or the air volume into the column to ensure that it matches the oxygen output and prevent the pressure rise of the upper column.
Second, the nitrogen plug on the column shall be strictly prevented, which is the key for adjustment. The decrease of oxygen output will easily cause the oxygen-enriched zone of the upper column to move upward. Therefore, it is necessary to appropriately increase the liquid nitrogen reflux or improve the liquid-air purity. Pay close attention to the purity of oxygen and nitrogen and the resistance of the upper column to avoid nitrogen mixing with oxygen products.
Third, stabilize the pressure and liquid level of the rectifying column. The control valve shall be operated slowly for a few times to prevent large fluctuation of the upper column pressure, argon fraction (in case of argon column), liquid air, liquid nitrogen and oxygen level. Coordinate with the control phase throttle valve to maintain the stability of rectification.
Fourthly, consider the argon system and outlet pressure. When there is an argon column, synchronously reduce the amount of argon withdrawn to avoid high nitrogen content of argon fraction; The oxygen outlet shall be stabilized first and then reduced to prevent impact on subsequent pipe network and users.
In addition, avoid long-time low-load operation, prevent reduction of rectification efficiency and increase of energy consumption, and adjust product structure or unit load for long-term reduction. Operation tips: first reduce air and then oxygen, stabilize pressure and stabilize liquid nitrogen proof plug, keep a close watch on purity liquid level, and synchronously adjust argon system.

DEAR Air Separation Solve YourWhat precautions shall be taken for the regulation of excess oxygen in the air separation unit?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
With the rapid growth of liquid air separation plant production and sales, and the global energy crunch, the prospects for the use of liquid air separation plant cold energy are very broad. The use of liquid air separation plant cold energy should be developed in the direction of integration, fully integrated and effective use of liquid air separation plant cold energy liquid air separation units, using circulating nitrogen through the heat exchanger to recycle liquid air separation plant cold, ...
2026.05.13
When the amount of processing air is reduced, the rising steam and reflux liquid in the upper column will be reduced, but the reflux ratio will not change. Therefore, the reduction of processing air in a small range will not affect the purity of oxygen and nitrogen, and the reduction of processing air volume will help to reduce the pressure of the upper and lower columns. However, according to the material balance, the production of oxygen and nitrogen will naturally decrease when the amount of processing air is reduced. If the amount of processing air is too small, there will be leakage on the tray. If the heat and mass exchange of the leaked liquid is not sufficient, the purity of oxygen and nitrogen will be greatly affected, and even the normal production can not be realized. Therefore, the minimum allowable load of distillation column is generally specified.
2026.05.12
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top