What is the function of air separation equipment air cooling tower water-proof pressure interlocking?

What is the function of air separation equipment air cooling tower water-proof pressure interlocking?
Jan 19, 2026
Author: DEAR AST

In the air separation equipment, the anti-entrained water pressure interlocking of air cooling tower plays an important role in safety protection.
The air cooling tower is the key place for air cooling, where the air and cooling water exchange heat. However, if the pressure is abnormal during operation, it is very easy to cause water entrainment problem, affecting the stable operation of equipment and product quality. The pressure interlock system monitors the relevant pressure parameters.
When the outlet pressure of the air compressor is abnormally reduced, it means that the air entering the air cooling tower may be insufficient, the air cooling effect will become worse, and the water vapor is more likely to condense and be entrained. At this time, the pressure interlocking responds quickly and automatically adjusts the subsequent process parameters to reduce the air flow entering the air cooling tower and prevent the water entrainment due to uneven cooling caused by insufficient air.
If the pressure of circulating water pump fluctuates and the cooling water supply is unstable, the air cooling will also be affected. The pressure interlocking can detect this change in time, regulate the cooling water flow or give an alarm to avoid water entrainment due to cooling water problems.
Through this accurate pressure interlocking control, the real-time control of the operation status of the air cooling tower is realized, the efficient, stable and safe operation of the air separation equipment is guaranteed, and the subsequent air separation processes are provided with reliable guarantee.

DEAR Air Separation Solve YourWhat is the function of air separation equipment air cooling tower water-proof pressure interlocking?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
2026.08.18
What is the oxygen extraction rate?
2026.08.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top