How to prevent water entrainment of air cooling tower of air separation equipment?

How to prevent water entrainment of air cooling tower of air separation equipment?
Jan 14, 2026
Author: DEAR AST

In the air separation equipment, the water entrained in the air cooling tower will seriously affect the safety and efficiency of equipment operation, so effective measures shall be taken for prevention.
First, ensure that the operating parameters of the air cooling tower are stable. Strictly control the air temperature and pressure entering the air cooling tower to avoid uneven air cooling caused by parameter fluctuation and abnormal water vapor condensation. At the same time, reasonably adjust the flow and temperature of the cooling water, and timely adjust according to the change of air load, so that the cooling water and air can fully exchange heat and reduce the steam entrainment.
Secondly, the equipment shall be inspected and maintained regularly. Regularly clean the packing in the air cooling tower to prevent blocking or damage of the packing and affect the airflow distribution and cooling effect. Check the nozzle to ensure that the spray is uniform and avoid water drops caused by excessive local water volume. Regularly check and replace the demister to ensure that it can effectively intercept water droplets and prevent water vapor from entering the subsequent system with air.
Moreover, strengthen the training of operators. Improve the operators' familiarity with the operating principle and operating procedures of the air cooling tower, so that they can accurately judge the equipment operation status and timely handle abnormal conditions. The startup and shutdown and load adjustment of equipment shall be carried out in strict accordance with the operation process to avoid the water entrainment problem caused by improper operation.
Through the above measures, from the aspects of operating parameter control, equipment maintenance and personnel operation, it can effectively prevent the air cooling tower of the air separation equipment from carrying water and ensure the stable operation of the equipment.

DEAR Air Separation Solve YourHow to prevent water entrainment of air cooling tower of air separation equipment?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
With the rapid growth of liquid air separation plant production and sales, and the global energy crunch, the prospects for the use of liquid air separation plant cold energy are very broad. The use of liquid air separation plant cold energy should be developed in the direction of integration, fully integrated and effective use of liquid air separation plant cold energy liquid air separation units, using circulating nitrogen through the heat exchanger to recycle liquid air separation plant cold, ...
2026.05.13
When the amount of processing air is reduced, the rising steam and reflux liquid in the upper column will be reduced, but the reflux ratio will not change. Therefore, the reduction of processing air in a small range will not affect the purity of oxygen and nitrogen, and the reduction of processing air volume will help to reduce the pressure of the upper and lower columns. However, according to the material balance, the production of oxygen and nitrogen will naturally decrease when the amount of processing air is reduced. If the amount of processing air is too small, there will be leakage on the tray. If the heat and mass exchange of the leaked liquid is not sufficient, the purity of oxygen and nitrogen will be greatly affected, and even the normal production can not be realized. Therefore, the minimum allowable load of distillation column is generally specified.
2026.05.12
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top