How to prevent water entrainment of air cooling tower of air separation equipment?

How to prevent water entrainment of air cooling tower of air separation equipment?
Jan 14, 2026
Author: DEAR AST

In the air separation equipment, the water entrained in the air cooling tower will seriously affect the safety and efficiency of equipment operation, so effective measures shall be taken for prevention.
First, ensure that the operating parameters of the air cooling tower are stable. Strictly control the air temperature and pressure entering the air cooling tower to avoid uneven air cooling caused by parameter fluctuation and abnormal water vapor condensation. At the same time, reasonably adjust the flow and temperature of the cooling water, and timely adjust according to the change of air load, so that the cooling water and air can fully exchange heat and reduce the steam entrainment.
Secondly, the equipment shall be inspected and maintained regularly. Regularly clean the packing in the air cooling tower to prevent blocking or damage of the packing and affect the airflow distribution and cooling effect. Check the nozzle to ensure that the spray is uniform and avoid water drops caused by excessive local water volume. Regularly check and replace the demister to ensure that it can effectively intercept water droplets and prevent water vapor from entering the subsequent system with air.
Moreover, strengthen the training of operators. Improve the operators' familiarity with the operating principle and operating procedures of the air cooling tower, so that they can accurately judge the equipment operation status and timely handle abnormal conditions. The startup and shutdown and load adjustment of equipment shall be carried out in strict accordance with the operation process to avoid the water entrainment problem caused by improper operation.
Through the above measures, from the aspects of operating parameter control, equipment maintenance and personnel operation, it can effectively prevent the air cooling tower of the air separation equipment from carrying water and ensure the stable operation of the equipment.

DEAR Air Separation Solve YourHow to prevent water entrainment of air cooling tower of air separation equipment?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top