当前位置: Home / Faq / Small air separation FAQ /

Common causes and solutions for high outlet air temperature of air separation tower of air separation equipment?

Common causes and solutions for high outlet air temperature of air separation tower of air separation equipment?
Jan 13, 2026
Author: DEAR AST

Higher outlet air temperature of air cooling tower will increase adsorption load of subsequent molecular sieve and affect stable operation of air separation system. Common causes and corresponding solutions are as follows:
1、 Cooling/chilled water system problems, such as insufficient water supply, blocked piping or too high chilled water temperature. Check the operating state of the water pump, clean the impurities in the pipeline and ensure sufficient water supply; At the same time, check the chiller unit and adjust the parameters to make the chilled water temperature meet the standard.
2、 The equipment operates abnormally, including the blockage of spray device in the air cooling tower, the decrease of heat exchange efficiency due to the scaling of packing, or the air flow distribution due to the failure of overhead water collector. Shut down the machine to overhaul the spray device, clean the packing and replace the damaged water collector.
3、 Failure of instrument and control, such as inaccurate temperature measuring instrument and abnormal liquid level control system, resulting in abnormal liquid level in the column. Timely check or replace the temperature measuring instrument, check the level transmitter and control valve, and restore the normal level control.
4、 Operation and environmental factors, such as sudden increase of air intake, too high ambient temperature, or foam entrainment. Smoothly adjust the intake load and optimize the ventilation and cooling of the workshop; In case of foam, add defoaming agent and check the water quality to standardize the operation process.

DEAR Air Separation Solve YourCommon causes and solutions for high outlet air temperature of air separation tower of air separation equipment?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top