How to operate in case of water entrainment in air cooling tower of air separation equipment?

How to operate in case of water entrainment in air cooling tower of air separation equipment?
Jan 04, 2026
Author: DEAR AST

When water entrainment occurs to the air cooling tower of air separation equipment, effective measures must be taken quickly to prevent the problem from worsening and affecting the stable operation of the entire air separation system.
Once water entrainment is detected, immediately shut down the circulating water pump. This is because a continuous supply of cooling water intensifies the entrainment of water, allowing more water to be entrained by air into the subsequent system, causing greater damage to the equipment. Then, vent the air compressor to reduce the air pressure in the system and avoid more unstable factors caused by abnormal pressure. At the same time, quickly close the air inlet purifier or air inlet valve, and cut off the channels for air with water to enter the key links such as subsequent rectification to prevent water from polluting the subsequent equipment and products.
Organize professionals to carry out comprehensive inspection on the air cooling tower after the above emergency operations are completed. Focus on checking whether the filler is blocked, whether the spray nozzle is uniform, whether the demister is damaged, etc. The abnormality of these parts is often the common cause of entrainment of water. Find out the specific cause and carry out targeted treatment, such as cleaning the blocked packing, replacing the damaged nozzle or demister, etc.
When the problem is completely solved and the system is confirmed to be normal, the circulating water pump, air compressor and other equipment can be gradually restarted according to the operating procedures to restore the normal operation of the air separation system and ensure the production safety and product quality.

DEAR Air Separation Solve YourHow to operate in case of water entrainment in air cooling tower of air separation equipment?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top