当前位置: Home / Faq / Air separation parts FAQ /

What are the key points for daily maintenance of air compressors in the operation system of air separation equipment?

What are the key points for daily maintenance of air compressors in the operation system of air separation equipment?
Dec 08, 2025
Author: DEAR AST

In the operation system of air separation equipment, the air compressor is the core component, and its stable operation is crucial. Daily maintenance work cannot be ignored.
Firstly, during the operation of the air compressor, lubricating oil plays a crucial role in cooling, sealing, and lubrication. Ensure that the oil level is within the normal range. If the oil level is too low, it will cause insufficient lubrication and exacerbate component wear; If the oil level is too high, it may cause problems such as increased oil temperature and fuel consumption. At the same time, it is important to pay attention to the quality of the lubricating oil and replace it regularly to avoid affecting the performance of the air compressor due to deteriorating oil quality.
Secondly, it is necessary to regularly clean the air filter to ensure its permeability. In addition, the cooler should be cleaned to prevent poor heat dissipation from causing high oil and exhaust temperatures.
Furthermore, during long-term operation of the air compressor, vibration may cause loosening of bolts and other fasteners, posing a safety hazard. Regularly check and tighten the bolts of each connecting part to ensure stable operation of the equipment.
Finally, closely monitor the exhaust pressure, temperature, current and other parameters of the air compressor. If there are abnormal fluctuations, the cause should be promptly investigated and dealt with to prevent the fault from expanding. Through meticulous daily maintenance, the service life of the air compressor can be effectively extended, ensuring the stable operation of the air separation equipment.

DEAR Air Separation Solve YourWhat are the key points for daily maintenance of air compressors in the operation system of air separation equipment?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification