How to troubleshoot sudden drop of main cooling liquid level of air separation equipment?

How to troubleshoot sudden drop of main cooling liquid level of air separation equipment?
Nov 27, 2025
Author: DEAR AST

During the operation and maintenance of air separation equipment, the sudden drop of main cooling liquid level is an emergency and can be eliminated according to the following steps.
Check the instrument display first. Confirm that the level gauge is working properly and check for fault codes or abnormal indications. Compare the on-site liquid level gauge with other relevant liquid level monitoring data, if the deviation is large, it may be caused by the liquid level gauge failure, which shall be calibrated or replaced in time to ensure that accurate liquid level information is obtained.
Troubleshoot the leakage. The main cooling equipment body, pipe connection and valve sealing are all key inspection parts. Smear the possible leakage part with soapy water and observe whether there is bubble; The professional leak detector can also be used to improve the troubleshooting efficiency. In case of leakage, measures such as fastening and repair welding shall be taken immediately.
Pay attention to the liquid inlet. Check whether the opening of liquid air and liquid oxygen inlet valves is proper, and whether the liquid inlet pipe is blocked, which can be judged by observing the change of liquid inlet pressure and flow. At the same time, confirm the operating state of the liquid inlet pump. If the pump fails, the liquid inlet will be insufficient, and it shall be repaired or replaced in time.
Analyze operating factors. Review recent operating records for excessive venting, large fluctuations in operating pressure, etc. If any, the operating parameters shall be adjusted in time to stabilize the operation of the equipment and gradually restore the main cooling liquid level to normal, so as to ensure the safe and stable production of the air separation equipment.

DEAR Air Separation Solve YourHow to troubleshoot sudden drop of main cooling liquid level of air separation equipment?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top