How to troubleshoot sudden drop of main cooling liquid level of air separation equipment?

How to troubleshoot sudden drop of main cooling liquid level of air separation equipment?
Nov 27, 2025
Author: DEAR AST

During the operation and maintenance of air separation equipment, the sudden drop of main cooling liquid level is an emergency and can be eliminated according to the following steps.
Check the instrument display first. Confirm that the level gauge is working properly and check for fault codes or abnormal indications. Compare the on-site liquid level gauge with other relevant liquid level monitoring data, if the deviation is large, it may be caused by the liquid level gauge failure, which shall be calibrated or replaced in time to ensure that accurate liquid level information is obtained.
Troubleshoot the leakage. The main cooling equipment body, pipe connection and valve sealing are all key inspection parts. Smear the possible leakage part with soapy water and observe whether there is bubble; The professional leak detector can also be used to improve the troubleshooting efficiency. In case of leakage, measures such as fastening and repair welding shall be taken immediately.
Pay attention to the liquid inlet. Check whether the opening of liquid air and liquid oxygen inlet valves is proper, and whether the liquid inlet pipe is blocked, which can be judged by observing the change of liquid inlet pressure and flow. At the same time, confirm the operating state of the liquid inlet pump. If the pump fails, the liquid inlet will be insufficient, and it shall be repaired or replaced in time.
Analyze operating factors. Review recent operating records for excessive venting, large fluctuations in operating pressure, etc. If any, the operating parameters shall be adjusted in time to stabilize the operation of the equipment and gradually restore the main cooling liquid level to normal, so as to ensure the safe and stable production of the air separation equipment.

DEAR Air Separation Solve YourHow to troubleshoot sudden drop of main cooling liquid level of air separation equipment?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
How to troubleshoot sudden drop of main cooling liquid level of air separation equipment?
2025.11.27
The nitrogen from the top of the upper tower is piped through the nitrogen gas pipeline, reheated through the main heat exchanger of the colder tower, and a portion of the nitrogen is pumped out, then combined with the first pipeline and a portion of the nitrogen vaporised in the liquefier in the third pipeline before going to the main vessel. The first raw material air pipeline is heated up and out of the cold box in liquid air separation plant, then goes to the high pressure heat exchanger of ...
2025.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top